TY - JOUR
T1 - Selection Criteria in the Era of Perfect Competition for Drug-Eluting Stents in Association With Operator Volumes
T2 - An Operator-Volume Analysis of the Selection DES Study
AU - Hashimoto, Satoru
AU - Motozawa, Yoshihiro
AU - Mano, Toshiki
N1 - Publisher Copyright:
© Cardiol Res and Elmer Press Inc™
PY - 2024
Y1 - 2024
N2 - Background: This study aimed to explore the factors influencing the drug-eluting stent (DES) selection criteria of cardiologists in association with percutaneous coronary intervention (PCI) volumes and to determine whether they value further DES improvements and modifications. Methods: The survey was conducted on a group of cardiologist operators from April 10 to 30, 2023. Results: The analysis included 126 operators who answered the questions. Of these, low-, intermediate-, and high-volume operators accounted for 49 (38.9%), 47 (37.3%), and 30 (23.8%), respectively. Overall, Xience™ everolimus-eluting stent (CoCr-EES) was most frequently used, with?> 70% of cardiologists using it in?> 20% of their PCI practice. The percentage of selection by low-, intermediate-, and high-volume operators among the DESs used demonstrated no difference, except for dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo® stent (DTS). Logistic regression analysis revealed that low-volume operators are less likely to be affected in terms of company/sales representative (odds ratio (OR): 0.402, P = 0.031) and bending lesions (OR: 0.339, P = 0.037) for selecting DES. Low-volume operators less frequently selected Resolute Onyx™ zotarolimus-eluting stents (OR: 0.689, P = 0.043) and DTS (Drug-Eluting Stents) (OR: 0.361, P = 0.006) for PCI. Conclusions: The current study results indicate that patient background, DES performance, and product specifications were not criteria for DES selection in cardiologists with different PCI volumes in routine PCI.
AB - Background: This study aimed to explore the factors influencing the drug-eluting stent (DES) selection criteria of cardiologists in association with percutaneous coronary intervention (PCI) volumes and to determine whether they value further DES improvements and modifications. Methods: The survey was conducted on a group of cardiologist operators from April 10 to 30, 2023. Results: The analysis included 126 operators who answered the questions. Of these, low-, intermediate-, and high-volume operators accounted for 49 (38.9%), 47 (37.3%), and 30 (23.8%), respectively. Overall, Xience™ everolimus-eluting stent (CoCr-EES) was most frequently used, with?> 70% of cardiologists using it in?> 20% of their PCI practice. The percentage of selection by low-, intermediate-, and high-volume operators among the DESs used demonstrated no difference, except for dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo® stent (DTS). Logistic regression analysis revealed that low-volume operators are less likely to be affected in terms of company/sales representative (odds ratio (OR): 0.402, P = 0.031) and bending lesions (OR: 0.339, P = 0.037) for selecting DES. Low-volume operators less frequently selected Resolute Onyx™ zotarolimus-eluting stents (OR: 0.689, P = 0.043) and DTS (Drug-Eluting Stents) (OR: 0.361, P = 0.006) for PCI. Conclusions: The current study results indicate that patient background, DES performance, and product specifications were not criteria for DES selection in cardiologists with different PCI volumes in routine PCI.
KW - Annual operator volume
KW - Drug-eluting stent
KW - Percutaneous coronary intervention
UR - http://www.scopus.com/inward/record.url?scp=85199307006&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85199307006&partnerID=8YFLogxK
U2 - 10.14740/cr1651
DO - 10.14740/cr1651
M3 - Article
AN - SCOPUS:85199307006
SN - 1923-2829
VL - 15
SP - 189
EP - 197
JO - Cardiology Research
JF - Cardiology Research
IS - 3
ER -