TY - JOUR
T1 - Shock Index and Postpartum Hemorrhage in Vaginal Deliveries
T2 - A Multicenter Retrospective Study
AU - Ushida, Takafumi
AU - Kotani, Tomomi
AU - Imai, Kenji
AU - Nakano-Kobayashi, Tomoko
AU - Nakamura, Noriyuki
AU - Moriyama, Yoshinori
AU - Yoshida, Shigeru
AU - Yamashita, Mamoru
AU - Kajiyama, Hiroaki
AU - Kikkawa, Fumitaka
N1 - Publisher Copyright:
Copyright © 2020 by the Shock Society.
PY - 2021/3/1
Y1 - 2021/3/1
N2 - INTRODUCTION: Shock index (SI), calculated by dividing heart rate by systolic blood pressure, is used to detect hemodynamic instability and hypovolemia. In obstetric practice, limited evidence is available regarding its usefulness in detecting postpartum hemorrhage (PPH). We aimed to evaluate the usefulness of SI in detecting PPH in vaginal deliveries using clinical data from 12 primary maternity care units in Japan. MATERIAL AND METHODS: In this multicenter retrospective study, a total of 30,820 women who delivered vaginally at term at 12 primary maternity care units from January 2012 to December 2018 were included. Systolic and diastolic blood pressures and heart rate were measured at five different time points from admission to postpartum 2 h, and postpartum blood loss was measured. We evaluated the trend of average SI and the performance of each vital sign for detection of PPH. RESULTS: The trend of average SI during labor and the immediate postpartum period was approximately 0.7 in women with blood loss of <500 mL. SI from the time of delivery of the placenta increased with an increase in blood loss. SI had the highest area under the receiver operating characteristic curve of 0.699 [95% confidence interval (CI), 0.682-0.716] and 0.758 (95% CI, 0.729-0.788) for PPH of ≥1,000 and ≥1,500 mL, respectively. However, both sensitivity of SI (1.0) for PPH (≥1,000 mL; 29.9%, and ≥1,500 mL; 40.5%, respectively) and correlation between maximum SI and blood loss (coefficient of correlation, 0.263) were low. CONCLUSIONS: SI is a better parameter for PPH detection in vaginal deliveries than other vital signs. However, clinical judgment must incorporate other vital signs and symptoms associated with hypovolemic shock due to the low sensitivity of SI.
AB - INTRODUCTION: Shock index (SI), calculated by dividing heart rate by systolic blood pressure, is used to detect hemodynamic instability and hypovolemia. In obstetric practice, limited evidence is available regarding its usefulness in detecting postpartum hemorrhage (PPH). We aimed to evaluate the usefulness of SI in detecting PPH in vaginal deliveries using clinical data from 12 primary maternity care units in Japan. MATERIAL AND METHODS: In this multicenter retrospective study, a total of 30,820 women who delivered vaginally at term at 12 primary maternity care units from January 2012 to December 2018 were included. Systolic and diastolic blood pressures and heart rate were measured at five different time points from admission to postpartum 2 h, and postpartum blood loss was measured. We evaluated the trend of average SI and the performance of each vital sign for detection of PPH. RESULTS: The trend of average SI during labor and the immediate postpartum period was approximately 0.7 in women with blood loss of <500 mL. SI from the time of delivery of the placenta increased with an increase in blood loss. SI had the highest area under the receiver operating characteristic curve of 0.699 [95% confidence interval (CI), 0.682-0.716] and 0.758 (95% CI, 0.729-0.788) for PPH of ≥1,000 and ≥1,500 mL, respectively. However, both sensitivity of SI (1.0) for PPH (≥1,000 mL; 29.9%, and ≥1,500 mL; 40.5%, respectively) and correlation between maximum SI and blood loss (coefficient of correlation, 0.263) were low. CONCLUSIONS: SI is a better parameter for PPH detection in vaginal deliveries than other vital signs. However, clinical judgment must incorporate other vital signs and symptoms associated with hypovolemic shock due to the low sensitivity of SI.
UR - http://www.scopus.com/inward/record.url?scp=85102088794&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85102088794&partnerID=8YFLogxK
U2 - 10.1097/SHK.0000000000001634
DO - 10.1097/SHK.0000000000001634
M3 - Article
C2 - 32769817
AN - SCOPUS:85102088794
SN - 1073-2322
VL - 55
SP - 332
EP - 337
JO - Shock
JF - Shock
IS - 3
ER -