TY - JOUR
T1 - Simulation of the modulation transfer function dependent on the partial Fourier fraction in dynamic contrast enhancement magnetic resonance imaging
AU - Takatsu, Yasuo
AU - Ueyama, Tsuyoshi
AU - Miyati, Tosiaki
AU - Yamamura, Kenichirou
N1 - Publisher Copyright:
© 2016, Australasian College of Physical Scientists and Engineers in Medicine.
PY - 2016/12/1
Y1 - 2016/12/1
N2 - The image characteristics in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) depend on the partial Fourier fraction and contrast medium concentration. These characteristics were assessed and the modulation transfer function (MTF) was calculated by computer simulation. A digital phantom was created from signal intensity data acquired at different contrast medium concentrations on a breast model. The frequency images [created by fast Fourier transform (FFT)] were divided into 512 parts and rearranged to form a new image. The inverse FFT of this image yielded the MTF. From the reference data, three linear models (low, medium, and high) and three exponential models (slow, medium, and rapid) of the signal intensity were created. Smaller partial Fourier fractions, and higher gradients in the linear models, corresponded to faster MTF decline. The MTF more gradually decreased in the exponential models than in the linear models. The MTF, which reflects the image characteristics in DCE-MRI, was more degraded as the partial Fourier fraction decreased.
AB - The image characteristics in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) depend on the partial Fourier fraction and contrast medium concentration. These characteristics were assessed and the modulation transfer function (MTF) was calculated by computer simulation. A digital phantom was created from signal intensity data acquired at different contrast medium concentrations on a breast model. The frequency images [created by fast Fourier transform (FFT)] were divided into 512 parts and rearranged to form a new image. The inverse FFT of this image yielded the MTF. From the reference data, three linear models (low, medium, and high) and three exponential models (slow, medium, and rapid) of the signal intensity were created. Smaller partial Fourier fractions, and higher gradients in the linear models, corresponded to faster MTF decline. The MTF more gradually decreased in the exponential models than in the linear models. The MTF, which reflects the image characteristics in DCE-MRI, was more degraded as the partial Fourier fraction decreased.
UR - http://www.scopus.com/inward/record.url?scp=84983746055&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84983746055&partnerID=8YFLogxK
U2 - 10.1007/s13246-016-0474-6
DO - 10.1007/s13246-016-0474-6
M3 - Article
C2 - 27565662
AN - SCOPUS:84983746055
SN - 0158-9938
VL - 39
SP - 825
EP - 831
JO - Australasian Physical and Engineering Sciences in Medicine
JF - Australasian Physical and Engineering Sciences in Medicine
IS - 4
ER -