TY - JOUR
T1 - STIR turbo SE MR imaging vs. coregistered FDG-PET/CT
T2 - Quantitative and qualitative assessment of N-stage in non-small-cell lung cancer patients
AU - Ohno, Yoshiharu
AU - Koyama, Hisanobu
AU - Nogami, Munenobu
AU - Takenaka, Daisuke
AU - Yoshikawa, Takeshi
AU - Yoshimura, Masahiro
AU - Ohbayashi, Chiho
AU - Sugimura, Kazuro
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2007/10
Y1 - 2007/10
N2 - Purpose: To conduct a prospective comparison of the accuracy of short inversion time (TI) inversion-recovery (STIR) turbo spin-echo (SE) imaging and coregistered 2-[fluorine-18) fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) with computed tomography (CT) (coregistered FDG-PET/CT) to assess the N-stage in non-small-cell lung cancer (NSCLC) patients. Materials and Methods: A total of 115 consecutive NSCLC patients prospectively underwent CT, STIR turbo SE imaging, and FDG-PET, as well as surgical and pathological examinations. All STIR turbo SE images were obtained with a 0.9% saline phantom, which was placed alongside the chest wall of each patient, and coregistered FDG-PET/CTs were reconstructed using commercially available software. For quantitative assessments, the ratio of signal intensity (SI) of each lymph node to that of 0.9% saline phantom (lymph node-saline ratio [LSR]) and maximal standardized uptake value (SUVmax) of each lymph node were calculated. Feasible threshold values were determined by using the receiver operating characteristic (ROC) curve-based positive test, and diagnostic capabilities of N-stage were compared by McNemar's test on a per patient basis. Results: When feasible, threshold values were adopted, quantitative sensitivity (90.1%) and accuracy (92.2%) of STIR turbo SE imaging were significantly higher than those of quantitative and qualitative sensitivities (76.7% and 74.4%) and accuracies (83.5% and 82.6%) of coregistered FDG-PET/CT on a per patient basis (P < 0.05). Conclusion: STIR turbo SE imaging is at least as valid as coregistered FDG-PET/CT for quantitative and qualitative assessment of the N-stage for NSCLC patients.
AB - Purpose: To conduct a prospective comparison of the accuracy of short inversion time (TI) inversion-recovery (STIR) turbo spin-echo (SE) imaging and coregistered 2-[fluorine-18) fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) with computed tomography (CT) (coregistered FDG-PET/CT) to assess the N-stage in non-small-cell lung cancer (NSCLC) patients. Materials and Methods: A total of 115 consecutive NSCLC patients prospectively underwent CT, STIR turbo SE imaging, and FDG-PET, as well as surgical and pathological examinations. All STIR turbo SE images were obtained with a 0.9% saline phantom, which was placed alongside the chest wall of each patient, and coregistered FDG-PET/CTs were reconstructed using commercially available software. For quantitative assessments, the ratio of signal intensity (SI) of each lymph node to that of 0.9% saline phantom (lymph node-saline ratio [LSR]) and maximal standardized uptake value (SUVmax) of each lymph node were calculated. Feasible threshold values were determined by using the receiver operating characteristic (ROC) curve-based positive test, and diagnostic capabilities of N-stage were compared by McNemar's test on a per patient basis. Results: When feasible, threshold values were adopted, quantitative sensitivity (90.1%) and accuracy (92.2%) of STIR turbo SE imaging were significantly higher than those of quantitative and qualitative sensitivities (76.7% and 74.4%) and accuracies (83.5% and 82.6%) of coregistered FDG-PET/CT on a per patient basis (P < 0.05). Conclusion: STIR turbo SE imaging is at least as valid as coregistered FDG-PET/CT for quantitative and qualitative assessment of the N-stage for NSCLC patients.
UR - http://www.scopus.com/inward/record.url?scp=35148819832&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=35148819832&partnerID=8YFLogxK
U2 - 10.1002/jmri.21106
DO - 10.1002/jmri.21106
M3 - Article
C2 - 17896365
AN - SCOPUS:35148819832
SN - 1053-1807
VL - 26
SP - 1071
EP - 1080
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 4
ER -