The influence of the time activity variation on dynamic SPECT images in camera based SPECT

H. Maeda, K. Takeda, K. Matsumura, T. Nakagawa, T. Kitano, K. Ejiri, T. Kondou, A. Takeuchi, Hiroshi Toyama, G. Takeshita, S. Koga, T. Ichihara

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Image quality of dynamic single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time activity variation of the tracer such as accumulation and excretion in the object's organ. Especially at the early time after injection of radionuclide, artifacts may occur strongly in the SPECT images. Simulated and experimental projection data of line sources and Jaszczak phantom were altered by sequentially weighting the projections with a function that varied linearly with time. With a variation of object activity given by linearly decaying functions, the main effect observed on the SPECT images obtained from simulated line sources was an elliptical deformation on the object. If the changing rate (R (t + 1)R(t))/R(t) x 100 remained within 20% during acquisition, this deformation of SPECT images of line sources was not noticeable visually and resolution (FWHM) of line sources scarcely was degraded. In renal dynamic SPECT study using 99m TcDTPA, the image quality of the first scan (30 sec) was considerably degraded. However, the changing rates after the third scan were less than 20% on the mean of l0 kidneys and the image quality was not noticeable visually.

Original languageEnglish
Pages (from-to)27-34
Number of pages8
JournalKakuigaku
Volume28
Issue number1
Publication statusPublished - 01-01-1991
Externally publishedYes

Fingerprint

Single-Photon Emission-Computed Tomography
Kidney
Gamma Cameras
Information Storage and Retrieval
Radioisotopes
Artifacts
Injections

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

Maeda, H., Takeda, K., Matsumura, K., Nakagawa, T., Kitano, T., Ejiri, K., ... Ichihara, T. (1991). The influence of the time activity variation on dynamic SPECT images in camera based SPECT. Kakuigaku, 28(1), 27-34.
Maeda, H. ; Takeda, K. ; Matsumura, K. ; Nakagawa, T. ; Kitano, T. ; Ejiri, K. ; Kondou, T. ; Takeuchi, A. ; Toyama, Hiroshi ; Takeshita, G. ; Koga, S. ; Ichihara, T. / The influence of the time activity variation on dynamic SPECT images in camera based SPECT. In: Kakuigaku. 1991 ; Vol. 28, No. 1. pp. 27-34.
@article{6b3430436aa54833b8ee138d3f40f224,
title = "The influence of the time activity variation on dynamic SPECT images in camera based SPECT",
abstract = "Image quality of dynamic single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time activity variation of the tracer such as accumulation and excretion in the object's organ. Especially at the early time after injection of radionuclide, artifacts may occur strongly in the SPECT images. Simulated and experimental projection data of line sources and Jaszczak phantom were altered by sequentially weighting the projections with a function that varied linearly with time. With a variation of object activity given by linearly decaying functions, the main effect observed on the SPECT images obtained from simulated line sources was an elliptical deformation on the object. If the changing rate (R (t + 1)R(t))/R(t) x 100 remained within 20{\%} during acquisition, this deformation of SPECT images of line sources was not noticeable visually and resolution (FWHM) of line sources scarcely was degraded. In renal dynamic SPECT study using 99m TcDTPA, the image quality of the first scan (30 sec) was considerably degraded. However, the changing rates after the third scan were less than 20{\%} on the mean of l0 kidneys and the image quality was not noticeable visually.",
author = "H. Maeda and K. Takeda and K. Matsumura and T. Nakagawa and T. Kitano and K. Ejiri and T. Kondou and A. Takeuchi and Hiroshi Toyama and G. Takeshita and S. Koga and T. Ichihara",
year = "1991",
month = "1",
day = "1",
language = "English",
volume = "28",
pages = "27--34",
journal = "Kaku igaku. The Japanese journal of nuclear medicine",
issn = "0022-7854",
publisher = "Japanese Society of Nuclear Medicine",
number = "1",

}

Maeda, H, Takeda, K, Matsumura, K, Nakagawa, T, Kitano, T, Ejiri, K, Kondou, T, Takeuchi, A, Toyama, H, Takeshita, G, Koga, S & Ichihara, T 1991, 'The influence of the time activity variation on dynamic SPECT images in camera based SPECT', Kakuigaku, vol. 28, no. 1, pp. 27-34.

The influence of the time activity variation on dynamic SPECT images in camera based SPECT. / Maeda, H.; Takeda, K.; Matsumura, K.; Nakagawa, T.; Kitano, T.; Ejiri, K.; Kondou, T.; Takeuchi, A.; Toyama, Hiroshi; Takeshita, G.; Koga, S.; Ichihara, T.

In: Kakuigaku, Vol. 28, No. 1, 01.01.1991, p. 27-34.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The influence of the time activity variation on dynamic SPECT images in camera based SPECT

AU - Maeda, H.

AU - Takeda, K.

AU - Matsumura, K.

AU - Nakagawa, T.

AU - Kitano, T.

AU - Ejiri, K.

AU - Kondou, T.

AU - Takeuchi, A.

AU - Toyama, Hiroshi

AU - Takeshita, G.

AU - Koga, S.

AU - Ichihara, T.

PY - 1991/1/1

Y1 - 1991/1/1

N2 - Image quality of dynamic single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time activity variation of the tracer such as accumulation and excretion in the object's organ. Especially at the early time after injection of radionuclide, artifacts may occur strongly in the SPECT images. Simulated and experimental projection data of line sources and Jaszczak phantom were altered by sequentially weighting the projections with a function that varied linearly with time. With a variation of object activity given by linearly decaying functions, the main effect observed on the SPECT images obtained from simulated line sources was an elliptical deformation on the object. If the changing rate (R (t + 1)R(t))/R(t) x 100 remained within 20% during acquisition, this deformation of SPECT images of line sources was not noticeable visually and resolution (FWHM) of line sources scarcely was degraded. In renal dynamic SPECT study using 99m TcDTPA, the image quality of the first scan (30 sec) was considerably degraded. However, the changing rates after the third scan were less than 20% on the mean of l0 kidneys and the image quality was not noticeable visually.

AB - Image quality of dynamic single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time activity variation of the tracer such as accumulation and excretion in the object's organ. Especially at the early time after injection of radionuclide, artifacts may occur strongly in the SPECT images. Simulated and experimental projection data of line sources and Jaszczak phantom were altered by sequentially weighting the projections with a function that varied linearly with time. With a variation of object activity given by linearly decaying functions, the main effect observed on the SPECT images obtained from simulated line sources was an elliptical deformation on the object. If the changing rate (R (t + 1)R(t))/R(t) x 100 remained within 20% during acquisition, this deformation of SPECT images of line sources was not noticeable visually and resolution (FWHM) of line sources scarcely was degraded. In renal dynamic SPECT study using 99m TcDTPA, the image quality of the first scan (30 sec) was considerably degraded. However, the changing rates after the third scan were less than 20% on the mean of l0 kidneys and the image quality was not noticeable visually.

UR - http://www.scopus.com/inward/record.url?scp=0026064004&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026064004&partnerID=8YFLogxK

M3 - Article

C2 - 2020134

AN - SCOPUS:0026064004

VL - 28

SP - 27

EP - 34

JO - Kaku igaku. The Japanese journal of nuclear medicine

JF - Kaku igaku. The Japanese journal of nuclear medicine

SN - 0022-7854

IS - 1

ER -

Maeda H, Takeda K, Matsumura K, Nakagawa T, Kitano T, Ejiri K et al. The influence of the time activity variation on dynamic SPECT images in camera based SPECT. Kakuigaku. 1991 Jan 1;28(1):27-34.