Unexpected abnormal uptake in the breasts at dedicated breast PET: Incidentally detected small cancers or nonmalignant features?

Yoko Satoh, Utaroh Motosugi, Yoshie Omiya, Hiroshi Onishi

Research output: Contribution to journalArticlepeer-review

21 Citations (Scopus)

Abstract

OBJECTIVE. The purposes of this study were to evaluate the diagnostic performance of dedicated breast PET (dbPET) in cases of unexpected uptake and to define parameters associated with malignancy. MATERIALS AND METHODS. There are two types of high-resolution dbPET systems. One has two platelike detectors that compress the breast. This study was conducted with the other type, on which the patient lies prone and the breast hangs through a ring without compression. In total, 627 consecutively registered women underwent 18 F-FDG PET/CT and dbPET for pretherapeutic or posttherapeutic evaluation of breast cancer, prior suspicion of breast cancer, or cancer screening. Areas of abnormal FDG uptake, excluding known breast cancers, were analyzed. Uptake was morphologically categorized as focus, mass, or nonmass. Quantitative values were obtained, including the maximum standardized uptake value (SUV max ), peak SUV (SUV peak ), total lesion glycolysis (TLG), metabolic tumor volume (MTV), and lesion-to-background ratio (LBR). Clinical parameters were also assessed. Parameters were compared between breast cancer and noncancer groups; multivariate logistic regression analysis was performed. RESULTS. Of 40 instances of abnormal uptake, 13 were breast cancer. Morphologic features differed between cancer and noncancer groups (p = 0.0122). Among the cancers, 76.9% (10/13) had mass, 15.4% (2/13) had nonmass, and 7.7% (1/13) had focus uptake. Of noncancerous findings, 3.7% (1/27) were mass, 40.7% (11/27) nonmass, and 55.6% (15/27) focus uptake. SUV peak (p = 0.0234), TLG (p = 0.0017), MTV (p = 0.004), and LBR (p = 0.0432) also differed between groups. Results of multivariate analysis indicated that morphologic category at dbPET was independently associated with malignancy. CONCLUSION. Morphologic features of abnormal uptake at dbPET are associated with breast cancer and may be useful for diagnosing lesions of unknown histologic composition.

Original languageEnglish
Pages (from-to)443-449
Number of pages7
JournalAmerican Journal of Roentgenology
Volume212
Issue number2
DOIs
Publication statusPublished - 02-2019
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Unexpected abnormal uptake in the breasts at dedicated breast PET: Incidentally detected small cancers or nonmalignant features?'. Together they form a unique fingerprint.

Cite this