T1 - Usefulness of abdominal belt for restricting respiratory cardiac motion and improving image quality in myocardial perfusion PET
AU - Ichikawa, Yasutaka
AU - Tomita, Yoya
AU - Ishida, Masaki
AU - Kobayashi, Shigeki
AU - Takeda, Kan
AU - Sakuma, Hajime
N1 - Publisher Copyright:
© 2016, American Society of Nuclear Cardiology.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Background: The current study evaluated the usefulness of a belt technique for restricting respiratory motion of the heart and for improving image quality of 13N-ammonia myocardial PET/CT, and it assessed the tolerability of the belt technique in the clinical setting. Methods: Myocardial 13N-ammonia PET/CT scanning was performed in 8 volunteers on Discovery PET/CT 690 with an optical respiratory motion tracking system. Emission scans were performed with and without an abdominal belt. The amplitude of left ventricular (LV) respiratory motion was measured on respiratory-gated PET images. The degree of erroneous decreases in regional myocardial uptake was visually assessed on ungated PET images using a 5-point scale (0 = normal, 1/2/3 = mild/moderate/severe decrease, 4 = defect). The tolerability of the belt technique was evaluated in 53 patients. Results: All subjects tolerated the belt procedure. The amplitude of the LV respiratory motion decreased significantly with the belt (8.1 ± 7.1 vs 12.1 ± 6.1 mm, P = .0078). The belt significantly improved the image quality scores in the anterior (0.29 ± 0.81 vs 0.71 ± 1.04, P = .015) and inferior (0.33 ± 0.92 vs 1.04 ± 1.04, P < .0001) wall. No adverse events related to the belt technique were observed. Conclusions: The belt technique restricts LV respiratory motion and improves the image quality of myocardial PET/CT, and it is well tolerated by patients.
AB - Background: The current study evaluated the usefulness of a belt technique for restricting respiratory motion of the heart and for improving image quality of 13N-ammonia myocardial PET/CT, and it assessed the tolerability of the belt technique in the clinical setting. Methods: Myocardial 13N-ammonia PET/CT scanning was performed in 8 volunteers on Discovery PET/CT 690 with an optical respiratory motion tracking system. Emission scans were performed with and without an abdominal belt. The amplitude of left ventricular (LV) respiratory motion was measured on respiratory-gated PET images. The degree of erroneous decreases in regional myocardial uptake was visually assessed on ungated PET images using a 5-point scale (0 = normal, 1/2/3 = mild/moderate/severe decrease, 4 = defect). The tolerability of the belt technique was evaluated in 53 patients. Results: All subjects tolerated the belt procedure. The amplitude of the LV respiratory motion decreased significantly with the belt (8.1 ± 7.1 vs 12.1 ± 6.1 mm, P = .0078). The belt significantly improved the image quality scores in the anterior (0.29 ± 0.81 vs 0.71 ± 1.04, P = .015) and inferior (0.33 ± 0.92 vs 1.04 ± 1.04, P < .0001) wall. No adverse events related to the belt technique were observed. Conclusions: The belt technique restricts LV respiratory motion and improves the image quality of myocardial PET/CT, and it is well tolerated by patients.
UR - http://www.scopus.com/inward/record.url?scp=84982295385&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84982295385&partnerID=8YFLogxK
U2 - 10.1007/s12350-016-0623-z
DO - 10.1007/s12350-016-0623-z
M3 - Article
C2 - 27535413
AN - SCOPUS:84982295385
SN - 1071-3581
VL - 25
SP - 407
EP - 415
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
IS - 2
ER -