TY - JOUR
T1 - Validation of a newly developed immunoassay for TDP-43 in human plasma
AU - Matsuura, Sayo
AU - Tatebe, Harutsugu
AU - Higuchi, Makoto
AU - Tokuda, Takahiko
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/1/30
Y1 - 2024/1/30
N2 - The level of TAR DNA-binding protein 43 (TDP-43) in human blood was reported to have potential for use as a specific fluid biomarker, which represents disease-specific pathologies, for TDP-43 proteinopathies, including amyotrophic lateral sclerosis (ALS) and frontotemporal lobar degeneration (FTLD), which involves the aggregation and deposition of TDP-43 in the nervous system. However, at present, no reliable immunoassay can precisely quantify TDP-43 in human plasma and detect the difference in plasma TDP-43 levels between patients with ALS and controls. We recently developed a novel ultrasensitive immunoassay to quantify TDP-43 in human plasma, and in this study, we analytically validated this assay for application as a diagnostic biomarker for TDP-43 proteinopathies. The novel TDP-43 assay was assessed for the limit of detection, lower limit of quantification, intra- and interassay variation, linearity, parallelism, and analytical spike recoveries. Additionally, 17 pilot plasma samples obtained from patients with ALS and age-matched controls were analyzed using the assay. Our novel TDP-43 assay showed sufficient analytical performance to quantify TDP-43 in human plasma, with high sensitivity (LOD and LLOQ of 0.109 and 0.759 pg/mL, respectively) and high intra- and interassay precision (%CV) below 15 %. The experimental results for spike recovery, parallelism, and dilution linearity were also acceptable. In addition, despite a small sample size, significant differences in the plasma levels of TDP-43 were found between patients with ALS and controls (ALS, 66.63 ± 20.52 pg/mL; control, 42.70 ± 23.06 pg/mL, p = 0.0330). These results support that our novel TDP-43 assay is a reliable and innovative method for the quantification of TDP-43 in human plasma and can be a potential blood-based biomarker for the diagnosis of TDP-43 proteinopathies. Further large-scale studies are warranted to validate its usefulness.
AB - The level of TAR DNA-binding protein 43 (TDP-43) in human blood was reported to have potential for use as a specific fluid biomarker, which represents disease-specific pathologies, for TDP-43 proteinopathies, including amyotrophic lateral sclerosis (ALS) and frontotemporal lobar degeneration (FTLD), which involves the aggregation and deposition of TDP-43 in the nervous system. However, at present, no reliable immunoassay can precisely quantify TDP-43 in human plasma and detect the difference in plasma TDP-43 levels between patients with ALS and controls. We recently developed a novel ultrasensitive immunoassay to quantify TDP-43 in human plasma, and in this study, we analytically validated this assay for application as a diagnostic biomarker for TDP-43 proteinopathies. The novel TDP-43 assay was assessed for the limit of detection, lower limit of quantification, intra- and interassay variation, linearity, parallelism, and analytical spike recoveries. Additionally, 17 pilot plasma samples obtained from patients with ALS and age-matched controls were analyzed using the assay. Our novel TDP-43 assay showed sufficient analytical performance to quantify TDP-43 in human plasma, with high sensitivity (LOD and LLOQ of 0.109 and 0.759 pg/mL, respectively) and high intra- and interassay precision (%CV) below 15 %. The experimental results for spike recovery, parallelism, and dilution linearity were also acceptable. In addition, despite a small sample size, significant differences in the plasma levels of TDP-43 were found between patients with ALS and controls (ALS, 66.63 ± 20.52 pg/mL; control, 42.70 ± 23.06 pg/mL, p = 0.0330). These results support that our novel TDP-43 assay is a reliable and innovative method for the quantification of TDP-43 in human plasma and can be a potential blood-based biomarker for the diagnosis of TDP-43 proteinopathies. Further large-scale studies are warranted to validate its usefulness.
KW - Amyotrophic lateral sclerosis
KW - Immunoassay
KW - Plasma biomarker
KW - TDP-43
KW - Validation
UR - http://www.scopus.com/inward/record.url?scp=85182911827&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85182911827&partnerID=8YFLogxK
U2 - 10.1016/j.heliyon.2024.e24672
DO - 10.1016/j.heliyon.2024.e24672
M3 - Article
AN - SCOPUS:85182911827
SN - 2405-8440
VL - 10
JO - Heliyon
JF - Heliyon
IS - 2
M1 - e24672
ER -