In this study, we aimed to develop a hybrid method for automated detection of high-uptake regions in the breast and axilla using dedicated breast positron-emission tomography (db PET) and whole-body PET/computed tomography (CT) images. In our proposed method, high-uptake regions in the breast and axilla were detected using db PET images and whole-body PET/CT images. In db PET images, high-uptake regions in the breast were detected using adaptive thresholding technique based on the noise characteristics. In whole-body PET/CT images, the region of the breast that includes the axilla was first extracted using CT images. Next, high-uptake regions in the extracted breast region were detected on the PET images. By integration of the results of the two types of PET images, a final candidate region was obtained. In the experiments, the accuracy of extracting the region of the breast and detection ability was evaluated using clinical data. As a result, all breast regions were extracted correctly. The sensitivity of detection was 0.765, and the number of false positive cases were 1.8, which was 30% better than those on whole-body PET/CT alone. These results suggested that the proposed method, combining the two types of PET images is effective for improving detection performance.

元の言語English
ページ(範囲)260-267
ページ数8
ジャーナルRadiological Physics and Technology
12
発行部数3
DOI
出版物ステータスPublished - 01-09-2019

Fingerprint

breast
Breast
tomography
Tomography
Axilla
Positron-Emission Tomography
positrons
Body Image
Noise

All Science Journal Classification (ASJC) codes

  • Radiation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Radiology Nuclear Medicine and imaging

これを引用

Minoura, Natsuki ; Teramoto, Atsushi ; Ito, Akari ; Yamamuro, Osamu ; Nishio, Masami ; Saito, Kuniaki ; Fujita, Hiroshi. / A complementary scheme for automated detection of high-uptake regions on dedicated breast PET and whole-body PET/CT. :: Radiological Physics and Technology. 2019 ; 巻 12, 番号 3. pp. 260-267.
@article{3575cc4e53164957b24ab4acdb3eda74,
title = "A complementary scheme for automated detection of high-uptake regions on dedicated breast PET and whole-body PET/CT",
abstract = "In this study, we aimed to develop a hybrid method for automated detection of high-uptake regions in the breast and axilla using dedicated breast positron-emission tomography (db PET) and whole-body PET/computed tomography (CT) images. In our proposed method, high-uptake regions in the breast and axilla were detected using db PET images and whole-body PET/CT images. In db PET images, high-uptake regions in the breast were detected using adaptive thresholding technique based on the noise characteristics. In whole-body PET/CT images, the region of the breast that includes the axilla was first extracted using CT images. Next, high-uptake regions in the extracted breast region were detected on the PET images. By integration of the results of the two types of PET images, a final candidate region was obtained. In the experiments, the accuracy of extracting the region of the breast and detection ability was evaluated using clinical data. As a result, all breast regions were extracted correctly. The sensitivity of detection was 0.765, and the number of false positive cases were 1.8, which was 30{\%} better than those on whole-body PET/CT alone. These results suggested that the proposed method, combining the two types of PET images is effective for improving detection performance.",
author = "Natsuki Minoura and Atsushi Teramoto and Akari Ito and Osamu Yamamuro and Masami Nishio and Kuniaki Saito and Hiroshi Fujita",
year = "2019",
month = "9",
day = "1",
doi = "10.1007/s12194-019-00516-8",
language = "English",
volume = "12",
pages = "260--267",
journal = "Radiological Physics and Technology",
issn = "1865-0333",
publisher = "Springer Japan",
number = "3",

}

A complementary scheme for automated detection of high-uptake regions on dedicated breast PET and whole-body PET/CT. / Minoura, Natsuki; Teramoto, Atsushi; Ito, Akari; Yamamuro, Osamu; Nishio, Masami; Saito, Kuniaki; Fujita, Hiroshi.

:: Radiological Physics and Technology, 巻 12, 番号 3, 01.09.2019, p. 260-267.

研究成果: Article

TY - JOUR

T1 - A complementary scheme for automated detection of high-uptake regions on dedicated breast PET and whole-body PET/CT

AU - Minoura, Natsuki

AU - Teramoto, Atsushi

AU - Ito, Akari

AU - Yamamuro, Osamu

AU - Nishio, Masami

AU - Saito, Kuniaki

AU - Fujita, Hiroshi

PY - 2019/9/1

Y1 - 2019/9/1

N2 - In this study, we aimed to develop a hybrid method for automated detection of high-uptake regions in the breast and axilla using dedicated breast positron-emission tomography (db PET) and whole-body PET/computed tomography (CT) images. In our proposed method, high-uptake regions in the breast and axilla were detected using db PET images and whole-body PET/CT images. In db PET images, high-uptake regions in the breast were detected using adaptive thresholding technique based on the noise characteristics. In whole-body PET/CT images, the region of the breast that includes the axilla was first extracted using CT images. Next, high-uptake regions in the extracted breast region were detected on the PET images. By integration of the results of the two types of PET images, a final candidate region was obtained. In the experiments, the accuracy of extracting the region of the breast and detection ability was evaluated using clinical data. As a result, all breast regions were extracted correctly. The sensitivity of detection was 0.765, and the number of false positive cases were 1.8, which was 30% better than those on whole-body PET/CT alone. These results suggested that the proposed method, combining the two types of PET images is effective for improving detection performance.

AB - In this study, we aimed to develop a hybrid method for automated detection of high-uptake regions in the breast and axilla using dedicated breast positron-emission tomography (db PET) and whole-body PET/computed tomography (CT) images. In our proposed method, high-uptake regions in the breast and axilla were detected using db PET images and whole-body PET/CT images. In db PET images, high-uptake regions in the breast were detected using adaptive thresholding technique based on the noise characteristics. In whole-body PET/CT images, the region of the breast that includes the axilla was first extracted using CT images. Next, high-uptake regions in the extracted breast region were detected on the PET images. By integration of the results of the two types of PET images, a final candidate region was obtained. In the experiments, the accuracy of extracting the region of the breast and detection ability was evaluated using clinical data. As a result, all breast regions were extracted correctly. The sensitivity of detection was 0.765, and the number of false positive cases were 1.8, which was 30% better than those on whole-body PET/CT alone. These results suggested that the proposed method, combining the two types of PET images is effective for improving detection performance.

UR - http://www.scopus.com/inward/record.url?scp=85067683532&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85067683532&partnerID=8YFLogxK

U2 - 10.1007/s12194-019-00516-8

DO - 10.1007/s12194-019-00516-8

M3 - Article

C2 - 31129787

AN - SCOPUS:85067683532

VL - 12

SP - 260

EP - 267

JO - Radiological Physics and Technology

JF - Radiological Physics and Technology

SN - 1865-0333

IS - 3

ER -