A quantitative coronary angiography-matched comparison between a prospective randomised multicentre cutting balloon angioplasty and bare metal stent trial (REDUCE III) and the Rapamycin-Eluting Stent Evaluation at Rotterdam Cardiology Hospital (RESEARCH) study

  • Yukio Ozaki
  • , Pedro A. Lemos
  • , Tetsu Yamaguchi
  • , Takahiko Suzuki
  • , Masato Nakamura
  • , Tevfik F. Ismail
  • , Michihiko Kitayama
  • , Hideo Nishikawa
  • , Osamu Kato
  • , Patrick W. Serruys

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65±0.41 mm vs. 1.28±0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03±0.42 mm vs. 0.80±0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

本文言語英語
ページ(範囲)400-406
ページ数7
ジャーナルEuroIntervention
6
3
DOI
出版ステータス出版済み - 08-2010
外部発表はい

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を

All Science Journal Classification (ASJC) codes

  • 循環器および心血管医学

フィンガープリント

「A quantitative coronary angiography-matched comparison between a prospective randomised multicentre cutting balloon angioplasty and bare metal stent trial (REDUCE III) and the Rapamycin-Eluting Stent Evaluation at Rotterdam Cardiology Hospital (RESEARCH) study」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル