T1 - Accuracy validation of incident photon fluence on DQE for various measurement conditions and X-ray units
AU - Haba, Tomonobu
AU - Kondo, Shimpei
AU - Hayashi, Daiki
AU - Koyama, Shuji
PY - 2013/7
Y1 - 2013/7
N2 - Detective quantum efficiency (DQE) is widely used as a comprehensive metric for X-ray image evaluation in digital X-ray units. The incident photon fluence per air kerma (SNRin2) is necessary for calculating the DQE. The International Electrotechnical Commission (IEC) reports the SNR in2 under conditions of standard radiation quality, but this SNRin2 might not be accurate as calculated from the X-ray spectra emitted by an actual X-ray tube. In this study, we evaluated the error range of the SNRin2 presented by the IEC62220-1 report. We measured the X-ray spectra emitted by an X-ray tube under conditions of standard radiation quality of RQA5. The spectral photon fluence at each energy bin was multiplied by the photon energy and the mass energy absorption coefficient of air; then the air kerma spectrum was derived. The air kerma spectrum was integrated over the whole photon energy range to yield the total air kerma. The total photon number was then divided by the total air kerma. This value is the SNRin2. These calculations were performed for various measurement parameters and X-ray units. The percent difference between the calculated value and the standard value of RQA5 was up to 2.9 %. The error range was not negligibly small. Therefore, it is better to use the new SNRin2 of 30694 (1/(mm2 μGy)) than the current SNRin2 of 30174 (1/(mm2 μGy)).
AB - Detective quantum efficiency (DQE) is widely used as a comprehensive metric for X-ray image evaluation in digital X-ray units. The incident photon fluence per air kerma (SNRin2) is necessary for calculating the DQE. The International Electrotechnical Commission (IEC) reports the SNR in2 under conditions of standard radiation quality, but this SNRin2 might not be accurate as calculated from the X-ray spectra emitted by an actual X-ray tube. In this study, we evaluated the error range of the SNRin2 presented by the IEC62220-1 report. We measured the X-ray spectra emitted by an X-ray tube under conditions of standard radiation quality of RQA5. The spectral photon fluence at each energy bin was multiplied by the photon energy and the mass energy absorption coefficient of air; then the air kerma spectrum was derived. The air kerma spectrum was integrated over the whole photon energy range to yield the total air kerma. The total photon number was then divided by the total air kerma. This value is the SNRin2. These calculations were performed for various measurement parameters and X-ray units. The percent difference between the calculated value and the standard value of RQA5 was up to 2.9 %. The error range was not negligibly small. Therefore, it is better to use the new SNRin2 of 30694 (1/(mm2 μGy)) than the current SNRin2 of 30174 (1/(mm2 μGy)).
UR - http://www.scopus.com/inward/record.url?scp=84880286012&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880286012&partnerID=8YFLogxK
U2 - 10.1007/s12194-013-0215-4
DO - 10.1007/s12194-013-0215-4
M3 - Article
C2 - 23649923
AN - SCOPUS:84880286012
SN - 1865-0333
VL - 6
SP - 423
EP - 430
JO - Radiological Physics and Technology
JF - Radiological Physics and Technology
IS - 2
ER -