T1 - Aortic dissection false lumen treatment with novel shape memory polymer devices
AU - Yamanouchi, Dai
AU - Sakurai, Yusuke
AU - Nemoto, Masaru
AU - Matsuura, Sohei
AU - Maeno, Ryohei
N1 - Publisher Copyright:
© 2026 The Author(s)
PY - 2026/8
Y1 - 2026/8
N2 - In this case series, innovative shape memory polymer (SMP) devices were used to treat the aortic dissection false lumen (FL) of five patients. The open-cell, porous structure of expanded SMP contributes to its radiolucency, low radial force, and conformability. The devices were designed to address the unique needs of treating the FL: sufficiently large volume, detachable and stable to minimize migration risk, segmented for flexibility, and with a range of dimensions. All five cases were technically successful. A decrease in total aortic diameter, true lumen restoration, and FL reduction were observed through 6- to 12-month follow-up. The mean changes in maximum aorta diameter from preoperative measurements were −5.8 ± 6.9 mm (30 days, n = 5), −12.0 ± 9.4 mm (6 months, n = 4), and −9.3 ± 0.8 mm (12 months, n = 2). No SMP device/procedure-related complications occurred.
AB - In this case series, innovative shape memory polymer (SMP) devices were used to treat the aortic dissection false lumen (FL) of five patients. The open-cell, porous structure of expanded SMP contributes to its radiolucency, low radial force, and conformability. The devices were designed to address the unique needs of treating the FL: sufficiently large volume, detachable and stable to minimize migration risk, segmented for flexibility, and with a range of dimensions. All five cases were technically successful. A decrease in total aortic diameter, true lumen restoration, and FL reduction were observed through 6- to 12-month follow-up. The mean changes in maximum aorta diameter from preoperative measurements were −5.8 ± 6.9 mm (30 days, n = 5), −12.0 ± 9.4 mm (6 months, n = 4), and −9.3 ± 0.8 mm (12 months, n = 2). No SMP device/procedure-related complications occurred.
KW - Aneurysm
KW - Aortic dissection
KW - False lumen embolization
KW - Shape memory polymer
KW - Thoracic stent graft
UR - https://www.scopus.com/pages/publications/105041601568
UR - https://www.scopus.com/pages/publications/105041601568#tab=citedBy
U2 - 10.1016/j.jvscit.2026.102326
DO - 10.1016/j.jvscit.2026.102326
M3 - Article
AN - SCOPUS:105041601568
SN - 2468-4287
VL - 12
JO - Journal of Vascular Surgery Cases, Innovations and Techniques
JF - Journal of Vascular Surgery Cases, Innovations and Techniques
IS - 4
M1 - 102326
ER -