The conversion coefficients, H′(d,α)/φ, for monoenergetic positrons and positron-emitting radionuclides were calculated by using the user code UCICRPM of the Monte Carlo code EGS5 to estimate the radiation dose for medical staff involved in positron emission tomography examinations. From these coefficients, the dose equivalent rates per unit activity at 0.07 and 10 mm depths in a soft tissue for a straight-line source of 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG) were calculated by using the developed user code UCF18DOSE. The dose equivalent rates per unit activity at 0.07 and 10 mm depths were measured by using a personal dosemeter (DOSE3) under the same conditions as those considered in the calculation. The calculated dose equivalent rates per unit activity at 0.07 and 10 mm depths were 0.116 and 0.0352 pSv min-1 Bq-1, respectively, at 20 cm from the 18F-FDG injection tube.