TY - JOUR
T1 - Comparison of the Iowa Oral Performance Instrument and JMS tongue pressure measurement device
AU - Yoshikawa, Mineka
AU - Fukuoka, Tatsuyuki
AU - Mori, Takahiro
AU - Hiraoka, Aya
AU - Higa, Chiaki
AU - Kuroki, Azusa
AU - Takeda, Chiho
AU - Maruyama, Mariko
AU - Yoshida, Mitsuyoshi
AU - Tsuga, Kazuhiro
N1 - Publisher Copyright:
© 2020 Association for Dental Sciences of the Republic of China
PY - 2021/1
Y1 - 2021/1
N2 - Background/purpose: Tongue pressure measurement conveys important information about eating and swallowing function. The Iowa Oral Performance Instrument® (IOPI) and KAY Swallowing Workstation® are internationally used for tongue pressure measurement, but for legal reasons cannot be used in Japan; rather the JMS tongue pressure measurement device® has been approved for use in Japan. However, it is not clear whether measurement obtained with these devices are directly comparable. Materials and methods: This study investigated the correlation between the maximum tongue pressure data measured by the IOPI and the JMS tongue pressure measurement device in young healthy participants (34 males; 23.2 ± 2.0 years old, and 40 females; 21.4 ± 1.3 years old). Results: Measurements obtained with these two devices showed significant correlations in the total cohort, and in male and female participants, separately (P < 0.05). Conclusion: These findings demonstrate that the measurements obtained with the JMS device is comparable to those obtained with the IOPI. In Japan, JMS tongue pressure measurement device is used not only in dysphagia research field, but also geriatrics field, and extensive and detailed investigations has been carried out.
AB - Background/purpose: Tongue pressure measurement conveys important information about eating and swallowing function. The Iowa Oral Performance Instrument® (IOPI) and KAY Swallowing Workstation® are internationally used for tongue pressure measurement, but for legal reasons cannot be used in Japan; rather the JMS tongue pressure measurement device® has been approved for use in Japan. However, it is not clear whether measurement obtained with these devices are directly comparable. Materials and methods: This study investigated the correlation between the maximum tongue pressure data measured by the IOPI and the JMS tongue pressure measurement device in young healthy participants (34 males; 23.2 ± 2.0 years old, and 40 females; 21.4 ± 1.3 years old). Results: Measurements obtained with these two devices showed significant correlations in the total cohort, and in male and female participants, separately (P < 0.05). Conclusion: These findings demonstrate that the measurements obtained with the JMS device is comparable to those obtained with the IOPI. In Japan, JMS tongue pressure measurement device is used not only in dysphagia research field, but also geriatrics field, and extensive and detailed investigations has been carried out.
UR - http://www.scopus.com/inward/record.url?scp=85086153345&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85086153345&partnerID=8YFLogxK
U2 - 10.1016/j.jds.2020.06.005
DO - 10.1016/j.jds.2020.06.005
M3 - Article
AN - SCOPUS:85086153345
SN - 1991-7902
VL - 16
SP - 214
EP - 219
JO - Journal of Dental Sciences
JF - Journal of Dental Sciences
IS - 1
ER -