TY - JOUR
T1 - Comparison of the sit-up test and head-up tilt test for assessing blood pressure and hemodynamic responses in healthy young individuals
AU - Oyake, Kazuaki
AU - Murayama, Jun
AU - Tateishi, Takaki
AU - Mochida, Ayumi
AU - Matsumoto, Mao
AU - Tsujikawa, Masahiro
AU - Kondo, Kunitsugu
AU - Otaka, Yohei
AU - Momose, Kimito
N1 - Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/4/1
Y1 - 2022/4/1
N2 - Objective The sit-up test is used to assess orthostatic hypotension, without the use of a tilt table, in populations who are unable to stand. The primary objective of this study was to determine the differences in blood pressure and hemodynamic responses between the sit-up and head-up tilt tests. The secondary objective was to determine the hemodynamic responses related to changes in blood pressure during each test. Methods Nineteen healthy volunteers (nine males, aged 24.3 ± 2.4 years) underwent the sit-up and head-up tilt tests. Systolic and diastolic blood pressure, heart rate, stroke volume, cardiac output, and total peripheral resistance were measured. Results The increase in systolic blood pressure (15 ± 9 vs. 8 ± 8 mmHg) was greater, while the increase in heart rate (8 ± 5 vs. 12 ± 8 bpm) and reduction in stroke volume (-17 ± 10 vs. -21 ± 10 ml) were smaller during the sit-up test than during the head-up tilt test (P < 0.05). Additionally, the increases in blood pressure variables were significantly associated with the increase in total peripheral resistance (P < 0.05), but not with changes in other hemodynamic variables in both tests. Conclusion Although the magnitudes of changes in systolic blood pressure, heart rate, and stroke volume differed between the tests, the hemodynamic variable related to changes in blood pressure was the same for both tests. These results may contribute to the clinical application of the sit-up test for identifying the presence and hemodynamic mechanisms of orthostatic hypotension.
AB - Objective The sit-up test is used to assess orthostatic hypotension, without the use of a tilt table, in populations who are unable to stand. The primary objective of this study was to determine the differences in blood pressure and hemodynamic responses between the sit-up and head-up tilt tests. The secondary objective was to determine the hemodynamic responses related to changes in blood pressure during each test. Methods Nineteen healthy volunteers (nine males, aged 24.3 ± 2.4 years) underwent the sit-up and head-up tilt tests. Systolic and diastolic blood pressure, heart rate, stroke volume, cardiac output, and total peripheral resistance were measured. Results The increase in systolic blood pressure (15 ± 9 vs. 8 ± 8 mmHg) was greater, while the increase in heart rate (8 ± 5 vs. 12 ± 8 bpm) and reduction in stroke volume (-17 ± 10 vs. -21 ± 10 ml) were smaller during the sit-up test than during the head-up tilt test (P < 0.05). Additionally, the increases in blood pressure variables were significantly associated with the increase in total peripheral resistance (P < 0.05), but not with changes in other hemodynamic variables in both tests. Conclusion Although the magnitudes of changes in systolic blood pressure, heart rate, and stroke volume differed between the tests, the hemodynamic variable related to changes in blood pressure was the same for both tests. These results may contribute to the clinical application of the sit-up test for identifying the presence and hemodynamic mechanisms of orthostatic hypotension.
UR - http://www.scopus.com/inward/record.url?scp=85125683201&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85125683201&partnerID=8YFLogxK
U2 - 10.1097/MBP.0000000000000570
DO - 10.1097/MBP.0000000000000570
M3 - Article
C2 - 34629377
AN - SCOPUS:85125683201
SN - 1359-5237
VL - 27
SP - 79
EP - 86
JO - Blood Pressure Monitoring
JF - Blood Pressure Monitoring
IS - 2
ER -