メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Comparison of the utility of whole-body MRI with and without contrast-enhanced Quick 3D and double RF fat suppression techniques, conventional whole-body MRI, PET/CT and conventional examination for assessment of recurrence in NSCLC patients

  • Yoshiharu Ohno
  • , Mizuho Nishio
  • , Hisanobu Koyama
  • , Takeshi Yoshikawa
  • , Sumiaki Matsumoto
  • , Daisuke Takenaka
  • , Shinichiro Seki
  • , Maho Tsubakimoto
  • , Kazuro Sugimura

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Purpose The purpose of this study was to compare diagnostic capabilities for assessment of recurrence in non-small cell lung cancer (NSCLC) patients by contrast-enhanced whole-body MRI (CE-WB-MRI) with and without CE-Quick 3D and double RF fat suppression technique (DFS), FDG-PET/CT and conventional radiological examinations. Materials and methods A total of 134 pathologically proven and completely resected NSCLC patients (78 males, 56 females; mean age: 72 years) underwent FDG-PET/CT, CE-WB-MRI with and without Quick 3D and DFS at 3 T as well as conventional radiological examinations. The probability of recurrence was assessed with a 5-point scoring system on a per-patient basis, and final diagnosis was made by consensus between two readers. The capability for overall recurrence assessment by all the methods was compared by means of ROC analysis and their sensitivity, specificity and accuracy by means of McNemar's test. Results Although areas under the curve did not show any significant differences, specificity (100%) and accuracy (95.5%) of CE-WB-MRI with CE-Quick 3D and DFS were significantly higher than those of FDG-PET/CT (specificity: 93.6%, p = 0.02; accuracy: 89.6%, p = 0.01) and conventional radiological examinations (specificity: 92.7%, p = 0.01; accuracy: 91.0%, p = 0.03). In addition, specificity of CE-WB-MRI without CE-Quick 3D and DFS (100%) was significantly higher than that of FDG-PET/CT (p = 0.02) and conventional radiological examinations (p = 0.01). Conclusion Specificity and accuracy of CE-WB-MRI with CE-Quick 3D and DFS for assessment of recurrence in NSCLC patients are at least as high as, or higher than those of others.

本文言語英語
ページ(範囲)2018-2027
ページ数10
ジャーナルEuropean journal of radiology
82
11
DOI
出版ステータス出版済み - 11-2013
外部発表はい

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を

All Science Journal Classification (ASJC) codes

  • 放射線学、核医学およびイメージング

フィンガープリント

「Comparison of the utility of whole-body MRI with and without contrast-enhanced Quick 3D and double RF fat suppression techniques, conventional whole-body MRI, PET/CT and conventional examination for assessment of recurrence in NSCLC patients」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル