TY - JOUR
T1 - Deep learning reconstruction for brain diffusion-weighted imaging
T2 - efficacy for image quality improvement, apparent diffusion coefficient assessment, and intravoxel incoherent motion evaluation in in vitro and in vivo studies
AU - Hanamatsu, Satomu
AU - Murayama, Kazuhiro
AU - Ohno, Yoshiharu
AU - Yamamoto, Kaori
AU - Yui, Masao
AU - Toyama, Hiroshi
N1 - Publisher Copyright:
© 2023, Galenos Publishing House. All rights reserved.
PY - 2023/9
Y1 - 2023/9
N2 - PURPOSE Deep learning reconstruction (DLR) to improve imaging quality has already been introduced, but no studies have evaluated the effect of DLR on diffusion-weighted imaging (DWI) or intravoxel incoherent motion (IVIM) in in vitro or in vivo studies. The purpose of this study was to determine the effect of DLR for magnetic resonance imaging (MRI) in terms of image quality improvement, apparent diffusion coefficient (ADC) assessment, and IVIM index evaluation on DWI through in vitro and in vivo studies. METHODS For the in vitro study, a phantom recommended by the Quantitative Imaging Biomarkers Alliance was scanned and reconstructed with and without DLR, and 15 patients with brain tumors with normal-appearing gray and white matter examined using IVIM and reconstructed with and without DLR were included in the in vivo study. The ADCs of all phantoms for DWI with and without DLR, as well as the coefficient of variation percentage (CV%), and ADCs and IVIM indexes for each participant, were evaluated based on DWI with and without DLR by means of region-of-interest measurements. For the in vitro study, using the mean ADCs for all phantoms, a t-test was adopted to compare DWI with and without DLR. For the in vivo study, a Wilcoxon signed-rank test was used to compare the CV% between the two types of DWI. In addition, the Wilcoxon signed-rank test was used to compare the ADC, true diffusion coefficient (D), pseudodiffusion coefficient (D*), and percentage of water molecules in micro perfusion within 1 voxel (f) with and without DLR; the limits of agreement of each parameter were determined through a Bland–Altman analysis. RESULTS The in vitro study identified no significant differences between the ADC values for DWI with and without DLR (P > 0.05), and the CV% was significantly different for DWI with and without DLR (P < 0.05) when b values ≥250 s/mm2 were used. The in vivo study revealed that D* and f with and without DLR were significantly different (P < 0.001). The limits of agreement of the ADC, D, and D* values for DWI with and without DLR were determined as 0.00 ± 0.51 × 103, 0.00 ± 0.06 × 103, and 1.13 ± 4.04 × 103 mm2/s, respectively. The limits of agreement of the f values for DWI with and without DLR were determined as −0.01 ± 0.07. CONCLUSION Deep learning reconstruction for MRI has the potential to significantly improve DWI quality at higher b values. It has some effect on D* and f values in the IVIM index evaluation, but ADC and D values are less affected by DLR.
AB - PURPOSE Deep learning reconstruction (DLR) to improve imaging quality has already been introduced, but no studies have evaluated the effect of DLR on diffusion-weighted imaging (DWI) or intravoxel incoherent motion (IVIM) in in vitro or in vivo studies. The purpose of this study was to determine the effect of DLR for magnetic resonance imaging (MRI) in terms of image quality improvement, apparent diffusion coefficient (ADC) assessment, and IVIM index evaluation on DWI through in vitro and in vivo studies. METHODS For the in vitro study, a phantom recommended by the Quantitative Imaging Biomarkers Alliance was scanned and reconstructed with and without DLR, and 15 patients with brain tumors with normal-appearing gray and white matter examined using IVIM and reconstructed with and without DLR were included in the in vivo study. The ADCs of all phantoms for DWI with and without DLR, as well as the coefficient of variation percentage (CV%), and ADCs and IVIM indexes for each participant, were evaluated based on DWI with and without DLR by means of region-of-interest measurements. For the in vitro study, using the mean ADCs for all phantoms, a t-test was adopted to compare DWI with and without DLR. For the in vivo study, a Wilcoxon signed-rank test was used to compare the CV% between the two types of DWI. In addition, the Wilcoxon signed-rank test was used to compare the ADC, true diffusion coefficient (D), pseudodiffusion coefficient (D*), and percentage of water molecules in micro perfusion within 1 voxel (f) with and without DLR; the limits of agreement of each parameter were determined through a Bland–Altman analysis. RESULTS The in vitro study identified no significant differences between the ADC values for DWI with and without DLR (P > 0.05), and the CV% was significantly different for DWI with and without DLR (P < 0.05) when b values ≥250 s/mm2 were used. The in vivo study revealed that D* and f with and without DLR were significantly different (P < 0.001). The limits of agreement of the ADC, D, and D* values for DWI with and without DLR were determined as 0.00 ± 0.51 × 103, 0.00 ± 0.06 × 103, and 1.13 ± 4.04 × 103 mm2/s, respectively. The limits of agreement of the f values for DWI with and without DLR were determined as −0.01 ± 0.07. CONCLUSION Deep learning reconstruction for MRI has the potential to significantly improve DWI quality at higher b values. It has some effect on D* and f values in the IVIM index evaluation, but ADC and D values are less affected by DLR.
UR - http://www.scopus.com/inward/record.url?scp=85169848899&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85169848899&partnerID=8YFLogxK
U2 - 10.4274/dir.2023.232149
DO - 10.4274/dir.2023.232149
M3 - Article
C2 - 37554957
AN - SCOPUS:85169848899
SN - 1305-3825
VL - 29
SP - 664
EP - 673
JO - Diagnostic and Interventional Radiology
JF - Diagnostic and Interventional Radiology
IS - 5
ER -