メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: A nationwide cohort study

  • Takeshi Hasegawa
  • , Shigeru Nakai
  • , Ikuto Masakane
  • , Yuzo Watanabe
  • , Kunitoshi Iseki
  • , Yoshiharu Tsubakihara
  • , Tadao Akizawa

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Background The quality of dialysis fluid water might play an important role in hemodialysis patient outcomes. Although targeted endotoxin levels of dialysis fluid vary among countries, evidence of the contribution of these levels to mortality in hemodialysis patients is lacking. Study Design Retrospective cohort study using data from the Japan Renal Data Registry, a nationwide annual survey. Setting & Participants 130,781 patients receiving thrice-weekly in-center hemodialysis for more than 6 months were enrolled at 2,746 facilities in Japan at the end of 2006. None of the patients changed facility or treatment modality during 2007. Predictor Highest endotoxin level in dialysis fluid reported by each facility during 2006. Patients were categorized by facility endotoxin level into the following groups: <0.001, 0.001 to <0.01, 0.01 to <0.05, 0.05 to <0.1, and ≥0.1 EU/mL. Age, sex, dialysis vintage, diabetes mellitus as a primary cause of end-stage renal disease, Kt/V, normalized protein catabolic rate, dialysis session duration, serum albumin, and hemoglobin were measured as potential confounders. Outcome All-cause mortality, censored by transplantation; withdrawal from dialysis treatment; or end of follow-up. Results Of 130,781 hemodialysis patients, 91.2% had facility endotoxin levels below the limit set for dialysis fluid in Japan (<0.05 EU/mL). During a 1-year follow-up, 8,978 (6.9%) patients died of all causes. The rate of all-cause mortality at 1 year was highest in the ≥0.1-EU/mL category (88.0 deaths/1,000 person-years). Patients in the ≥0.1-EU/mL group exhibited an increased risk of all-cause mortality of 28% (95% CI, 10%-48%) compared to the <0.001-EU/mL group. Limitations Endotoxin level in dialysis fluid is reported as categorical data. No information about variation in endotoxin levels in dialysis fluid over time. Conclusions Higher facility endotoxin levels in dialysis fluid may be related to increased risk for all-cause mortality among hemodialysis patients. Correcting this modifiable facility water management practice might improve the outcome of hemodialysis patients.

本文言語英語
ページ(範囲)899-904
ページ数6
ジャーナルAmerican Journal of Kidney Diseases
65
6
DOI
出版ステータス出版済み - 01-06-2015
外部発表はい

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を
  2. SDG 6 - 安全な水とトイレを世界に
    SDG 6 安全な水とトイレを世界に

All Science Journal Classification (ASJC) codes

  • 腎臓病学

フィンガープリント

「Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: A nationwide cohort study」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル