メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Disruption of atherosclerotic neointima as a cause of very late stent thrombosis after bare metal stent implantation

  • Hirohiko Ando
  • , Hideki Ishii
  • , Daiji Yoshikawa
  • , Tadayuki Uetani
  • , Tetsuya Amano
  • , Toyoaki Murohara

研究成果: ジャーナルへの寄稿学術論文査読

2   !!Link opens in a new tab 被引用数 (Scopus)

抄録

A male who were implanted bare metal stent 11 years ago were admitted for acute coronay syndrome. Optical coherence tomography showed a neointimal disruption and integrated backscatter intravascular ultrasound revealed a lipid pool around the disrupted neointima, suggesting newly formed atherosclerotic neointima developed after bare metal stent implantation. The disruption of atherosclerotic neointima may represent a new potential mechanism of very late stent thrombosis after bare metal stent implantation.

本文言語英語
ページ(範囲)448-449
ページ数2
ジャーナルAmerican Journal of Cardiology
109
3
DOI
出版ステータス出版済み - 01-02-2012