Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators

Fumio Hashimoto, Atsushi Teramoto, Yasuki Asada, Shoichi Suzuki, Hiroshi Fujita

研究成果: Article

抄録

Recently, region-setting computed tomography (CT) has been studied as a region of interest imaging method. This technique can strongly reduce the radiation dose by limiting the irradiation field. Although mathematical studies have been performed for reduction of the truncation artifact, no experimental studies have been performed so far. In this study, we developed a three-dimensional region-setting CT system and evaluated its imaging properties. As an experimental system, we developed an X-ray CT system with multileaf collimators. In this system, truncated projection data can be captured by limiting of the radiation field. In addition, a truncated projection data correction was performed. Finally, image reconstruction was performed by use of the Feldkamp–Davis–Kress algorithm. In the experiments, the line profiles and the image quality of the reconstructed images were evaluated. The results suggested that the image quality of the proposed method is comparable to that of the original method. Furthermore, we confirmed that the radiation dose was reduced when this system was used. These results indicate that a 3D region-setting CT system using 6-channel multileaf collimators can reduce the radiation dose without in causing a degradation of image quality.

元の言語English
ページ(範囲)60-67
ページ数8
ジャーナルRadiological Physics and Technology
10
発行部数1
DOI
出版物ステータスPublished - 01-03-2017

Fingerprint

X Ray Computed Tomography
collimators
Radiography
tomography
Radiation
dosage
Tomography
x rays
radiation
projection
Computer-Assisted Image Processing
image reconstruction
Artifacts
radiation distribution
artifacts
degradation
irradiation
profiles
approximation

All Science Journal Classification (ASJC) codes

  • Radiation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Radiology Nuclear Medicine and imaging

これを引用

Hashimoto, Fumio ; Teramoto, Atsushi ; Asada, Yasuki ; Suzuki, Shoichi ; Fujita, Hiroshi. / Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators. :: Radiological Physics and Technology. 2017 ; 巻 10, 番号 1. pp. 60-67.
@article{e6eb5fe8d9b84f1bbb25ab5b72b95d32,
title = "Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators",
abstract = "Recently, region-setting computed tomography (CT) has been studied as a region of interest imaging method. This technique can strongly reduce the radiation dose by limiting the irradiation field. Although mathematical studies have been performed for reduction of the truncation artifact, no experimental studies have been performed so far. In this study, we developed a three-dimensional region-setting CT system and evaluated its imaging properties. As an experimental system, we developed an X-ray CT system with multileaf collimators. In this system, truncated projection data can be captured by limiting of the radiation field. In addition, a truncated projection data correction was performed. Finally, image reconstruction was performed by use of the Feldkamp–Davis–Kress algorithm. In the experiments, the line profiles and the image quality of the reconstructed images were evaluated. The results suggested that the image quality of the proposed method is comparable to that of the original method. Furthermore, we confirmed that the radiation dose was reduced when this system was used. These results indicate that a 3D region-setting CT system using 6-channel multileaf collimators can reduce the radiation dose without in causing a degradation of image quality.",
author = "Fumio Hashimoto and Atsushi Teramoto and Yasuki Asada and Shoichi Suzuki and Hiroshi Fujita",
year = "2017",
month = "3",
day = "1",
doi = "10.1007/s12194-016-0368-z",
language = "English",
volume = "10",
pages = "60--67",
journal = "Radiological Physics and Technology",
issn = "1865-0333",
publisher = "Springer Japan",
number = "1",

}

Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators. / Hashimoto, Fumio; Teramoto, Atsushi; Asada, Yasuki; Suzuki, Shoichi; Fujita, Hiroshi.

:: Radiological Physics and Technology, 巻 10, 番号 1, 01.03.2017, p. 60-67.

研究成果: Article

TY - JOUR

T1 - Dose reduction technique in diagnostic X-ray computed tomography by use of 6-channel multileaf collimators

AU - Hashimoto, Fumio

AU - Teramoto, Atsushi

AU - Asada, Yasuki

AU - Suzuki, Shoichi

AU - Fujita, Hiroshi

PY - 2017/3/1

Y1 - 2017/3/1

N2 - Recently, region-setting computed tomography (CT) has been studied as a region of interest imaging method. This technique can strongly reduce the radiation dose by limiting the irradiation field. Although mathematical studies have been performed for reduction of the truncation artifact, no experimental studies have been performed so far. In this study, we developed a three-dimensional region-setting CT system and evaluated its imaging properties. As an experimental system, we developed an X-ray CT system with multileaf collimators. In this system, truncated projection data can be captured by limiting of the radiation field. In addition, a truncated projection data correction was performed. Finally, image reconstruction was performed by use of the Feldkamp–Davis–Kress algorithm. In the experiments, the line profiles and the image quality of the reconstructed images were evaluated. The results suggested that the image quality of the proposed method is comparable to that of the original method. Furthermore, we confirmed that the radiation dose was reduced when this system was used. These results indicate that a 3D region-setting CT system using 6-channel multileaf collimators can reduce the radiation dose without in causing a degradation of image quality.

AB - Recently, region-setting computed tomography (CT) has been studied as a region of interest imaging method. This technique can strongly reduce the radiation dose by limiting the irradiation field. Although mathematical studies have been performed for reduction of the truncation artifact, no experimental studies have been performed so far. In this study, we developed a three-dimensional region-setting CT system and evaluated its imaging properties. As an experimental system, we developed an X-ray CT system with multileaf collimators. In this system, truncated projection data can be captured by limiting of the radiation field. In addition, a truncated projection data correction was performed. Finally, image reconstruction was performed by use of the Feldkamp–Davis–Kress algorithm. In the experiments, the line profiles and the image quality of the reconstructed images were evaluated. The results suggested that the image quality of the proposed method is comparable to that of the original method. Furthermore, we confirmed that the radiation dose was reduced when this system was used. These results indicate that a 3D region-setting CT system using 6-channel multileaf collimators can reduce the radiation dose without in causing a degradation of image quality.

UR - http://www.scopus.com/inward/record.url?scp=84978036633&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84978036633&partnerID=8YFLogxK

U2 - 10.1007/s12194-016-0368-z

DO - 10.1007/s12194-016-0368-z

M3 - Article

C2 - 27394728

AN - SCOPUS:84978036633

VL - 10

SP - 60

EP - 67

JO - Radiological Physics and Technology

JF - Radiological Physics and Technology

SN - 1865-0333

IS - 1

ER -