TY - JOUR
T1 - Effect of gait training using Welwalk on gait pattern in individuals with hemiparetic stroke
T2 - a cross-sectional study
AU - Ii, Takuma
AU - Hirano, Satoshi
AU - Imoto, Daisuke
AU - Otaka, Yohei
N1 - Publisher Copyright:
Copyright © 2023 Ii, Hirano, Imoto and Otaka.
PY - 2023
Y1 - 2023
N2 - Introduction: We aimed to explore the effect of gait training using Welwalk on gait patterns by comparing differences in gait patterns between robotic-assisted gait training using Welwalk and gait training using an orthosis in individuals with hemiparetic stroke. Methods: This study included 23 individuals with hemiparetic stroke who underwent gait training with Welwalk combined with overground gait training using an orthosis. Three-dimensional motion analysis on a treadmill was performed under two conditions for each participant: during gait training with Welwalk and with the ankle-foot orthosis. The spatiotemporal parameters and gait patterns were compared between the two conditions. Results: The affected step length was significantly longer, the step width was significantly wider, and the affected single support phase ratio was significantly higher in the Welwalk condition than in the orthosis condition. The index values of abnormal gait patterns were significantly lower while using Welwalk than in the orthosis condition. The following four indices were lower in the Welwalk condition: contralateral vaulting, insufficient knee flexion, excessive hip external rotation during the paretic swing phase, and paretic forefoot contact. Discussion: Gait training using Welwalk increased the affected step length, step width, and single support phase while suppressing abnormal gait patterns as compared to gait training using the ankle-foot orthosis. This study suggests that gait training using Welwalk may promote a more efficient gait pattern reacquisition that suppresses abnormal gait patterns. Trial registration: Prospectively registered in the Japan Registry of Clinical Trials (https://jrct.niph.go.jp; jRCTs042180152).
AB - Introduction: We aimed to explore the effect of gait training using Welwalk on gait patterns by comparing differences in gait patterns between robotic-assisted gait training using Welwalk and gait training using an orthosis in individuals with hemiparetic stroke. Methods: This study included 23 individuals with hemiparetic stroke who underwent gait training with Welwalk combined with overground gait training using an orthosis. Three-dimensional motion analysis on a treadmill was performed under two conditions for each participant: during gait training with Welwalk and with the ankle-foot orthosis. The spatiotemporal parameters and gait patterns were compared between the two conditions. Results: The affected step length was significantly longer, the step width was significantly wider, and the affected single support phase ratio was significantly higher in the Welwalk condition than in the orthosis condition. The index values of abnormal gait patterns were significantly lower while using Welwalk than in the orthosis condition. The following four indices were lower in the Welwalk condition: contralateral vaulting, insufficient knee flexion, excessive hip external rotation during the paretic swing phase, and paretic forefoot contact. Discussion: Gait training using Welwalk increased the affected step length, step width, and single support phase while suppressing abnormal gait patterns as compared to gait training using the ankle-foot orthosis. This study suggests that gait training using Welwalk may promote a more efficient gait pattern reacquisition that suppresses abnormal gait patterns. Trial registration: Prospectively registered in the Japan Registry of Clinical Trials (https://jrct.niph.go.jp; jRCTs042180152).
UR - http://www.scopus.com/inward/record.url?scp=85159028861&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85159028861&partnerID=8YFLogxK
U2 - 10.3389/fnbot.2023.1151623
DO - 10.3389/fnbot.2023.1151623
M3 - Article
AN - SCOPUS:85159028861
SN - 1662-5218
VL - 17
JO - Frontiers in Neurorobotics
JF - Frontiers in Neurorobotics
M1 - 1151623
ER -