TY - JOUR
T1 - Effects of ankle-foot orthoses on the stability of post-stroke hemiparetic gait
AU - Tsuchiyama, Kazuhiro
AU - Mukaino, Masahiko
AU - Ohtsuka, Kei
AU - Matsuda, Fumihiro
AU - Tanikawa, Hiroki
AU - Yamada, Junya
AU - Pongpipatpaiboon, Kannit
AU - Kanada, Yoshikiyo
AU - Saitoh, Eiichi
AU - Otaka, Yohei
N1 - Publisher Copyright:
© 2022 Edizioni Minerva Medica. All rights reserved.
PY - 2022/6
Y1 - 2022/6
N2 - BACKGROUND: Ankle-foot orthoses are used to improve gait stability in patients with post-stroke gait; however, there is not enough evidence to support their beneficial impact on gait stability. AIM: To investigate the effects of ankle-foot orthoses on post-stroke gait stability. DESIGN: An experimental study with repeated measurements of gait parameters with and without orthosis. SETTING: Inpatients and outpatients in the Fujita Health University Hospital, Toyoake, Japan. POPULATION: Thirty-two patients (22 males; mean age 48.3±20.0 years) with post-stroke hemiparesis participated in the study. METHODS: Three-dimensional treadmill gait analysis was performed with and without ankle-foot orthosis for each participant. Spatiotemporal parameters, their coefficient of variation, and margin of stability were evaluated. Toe clearance, another major target of orthosis, was also examined. The effect of orthosis in the patients with severe (not able to move within the full range of motion, defying gravity) and mild ankle impairment (able to move within the full range but have problem with speed and/or smoothness of the ankle movement) was compared. RESULTS: In the total group comparison, the decrease in the coefficient of variation of step width (P=0.012), and margin of stability on the paretic side (P=0.023) were observed. In the severe ankle impairment groups, the decreased in the coefficient of variation of the non-paretic step length (P=0.007), stride length (P=0.037), and step width (P=0.033) and margin of stability on the paretic side (P=0.006) were observed. No significant effects were observed in the mild ankle impairment group; rather, the coefficient of variation of non-paretic step length increased with the use of orthosis in this group (P=0.043); however, toe clearance increased with the use of ankle-foot orthosis (P=0.041). CONCLUSIONS: Ankle-foot orthoses improved gait stability indices; however, the effect was either not significant or showed possible worsening in the patients with mild ankle impairment, while the effect on toe clearance was significant. These results suggest that the effects of using orthoses in patients with mild impairment should be carefully evaluated. CLINICALREHABILITATIONIMPACT: Understanding the effects of ankle-foot orthoses on the stability of post-stroke gait and their relationship with ankle impairment severity may support clinical decision-making while prescribing orthosis for post-stroke hemiparesis.
AB - BACKGROUND: Ankle-foot orthoses are used to improve gait stability in patients with post-stroke gait; however, there is not enough evidence to support their beneficial impact on gait stability. AIM: To investigate the effects of ankle-foot orthoses on post-stroke gait stability. DESIGN: An experimental study with repeated measurements of gait parameters with and without orthosis. SETTING: Inpatients and outpatients in the Fujita Health University Hospital, Toyoake, Japan. POPULATION: Thirty-two patients (22 males; mean age 48.3±20.0 years) with post-stroke hemiparesis participated in the study. METHODS: Three-dimensional treadmill gait analysis was performed with and without ankle-foot orthosis for each participant. Spatiotemporal parameters, their coefficient of variation, and margin of stability were evaluated. Toe clearance, another major target of orthosis, was also examined. The effect of orthosis in the patients with severe (not able to move within the full range of motion, defying gravity) and mild ankle impairment (able to move within the full range but have problem with speed and/or smoothness of the ankle movement) was compared. RESULTS: In the total group comparison, the decrease in the coefficient of variation of step width (P=0.012), and margin of stability on the paretic side (P=0.023) were observed. In the severe ankle impairment groups, the decreased in the coefficient of variation of the non-paretic step length (P=0.007), stride length (P=0.037), and step width (P=0.033) and margin of stability on the paretic side (P=0.006) were observed. No significant effects were observed in the mild ankle impairment group; rather, the coefficient of variation of non-paretic step length increased with the use of orthosis in this group (P=0.043); however, toe clearance increased with the use of ankle-foot orthosis (P=0.041). CONCLUSIONS: Ankle-foot orthoses improved gait stability indices; however, the effect was either not significant or showed possible worsening in the patients with mild ankle impairment, while the effect on toe clearance was significant. These results suggest that the effects of using orthoses in patients with mild impairment should be carefully evaluated. CLINICALREHABILITATIONIMPACT: Understanding the effects of ankle-foot orthoses on the stability of post-stroke gait and their relationship with ankle impairment severity may support clinical decision-making while prescribing orthosis for post-stroke hemiparesis.
UR - http://www.scopus.com/inward/record.url?scp=85132455732&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85132455732&partnerID=8YFLogxK
U2 - 10.23736/S1973-9087.21.07048-9
DO - 10.23736/S1973-9087.21.07048-9
M3 - Article
C2 - 34498833
AN - SCOPUS:85132455732
SN - 1973-9087
VL - 58
SP - 352
EP - 362
JO - European Journal of Physical and Rehabilitation Medicine
JF - European Journal of Physical and Rehabilitation Medicine
IS - 3
ER -