メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Endoscopic closure of duodenal perforation with the over-the-scope-clipping system

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

抄録

Endoscopic treatment for superficial non-ampullary duodenal tumors is technically difficult and challenging due to the anatomical characteristics of the duodenum. It is frequently complicated by procedural accidents, such as perforation. Surgical repair has long been the standard treatment for acute iatrogenic gastrointestinal perforation. However, endoscopic closure has recently emerged as an attractive alternative. In the patient presented herein, the over-the-scope-clipping system (OTSC system) was found to be useful for closing a duodenal perforation that had occurred during endoscopic submucosal dissection. For endoscopists who perform endoscopic treatment of the duodenum, endoscopic closure with the OTSC system is considered to be a technique that is necessary to master.

本文言語英語
ページ(範囲)3131-3135
ページ数5
ジャーナルInternal Medicine
巻55
号21
DOI
出版ステータス出版済み - 2016
外部発表はい

All Science Journal Classification (ASJC) codes

  • 内科学

フィンガープリント

「Endoscopic closure of duodenal perforation with the over-the-scope-clipping system」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル