Estimation of the compliance of the human pulmonary “venous” system from pulmonary artery wedge pressure tracings

  • Senri Hirakawa
  • , Hiroyasu Ito
  • , Akira Sakai
  • , Akira Wakabayashi

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

12   !!Link opens in a new tab 被引用数 (Scopus)

抄録

Compliance (ΔV/ΔP) of the human pulmonary “venous” system was estimated in a total of 37 human subjects, from the pulmonary artery wedge (PAW) pressure tracings, using two equations, (ΔV/ΔP) slope = 0.4·k″·SV/(v-d) given in Appendix, and k″= 0.075 PAW + 0.9 given in Method. The estimated compliance of the pulmonary “venous” system was about 7 ~ 15 ml (mmHg)-1 in the control group, the patients of aortic valvular disease with physical capacity of Class I ~ III of the NYHA, and the patients of mitral stenosis with physical capacity of Class I. These values were in good agreement with that estimated by Guyton, i.e., 10 ml (mmHg)-1. For the entire population of pure mitral stenosis (n = 16), compliance (ΔV/ΔP) of the pulmonary “venous” system could be related to the PAW pressure by a regression curve of ΔV/ΔP = 1/(0.0106 PAW - 0.0173). We pointed out, in discussion, that the present method and an entirely different method using the pulmonary blood volume measurements and passive leg elevation, performed in one and the same patient simultaneously, gave fairly similar values of the compliance of the pulmonary “venous” system.

本文言語英語
ページ(範囲)15-23
ページ数9
ジャーナルJAPANESE CIRCULATION JOURNAL
巻45
号1
DOI
出版ステータス出版済み - 1981
外部発表はい

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を

All Science Journal Classification (ASJC) codes

  • 生理学
  • 循環器および心血管医学

フィンガープリント

「Estimation of the compliance of the human pulmonary “venous” system from pulmonary artery wedge pressure tracings」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル