Evaluation of the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels using particle and heavy ion transport code system: PHITS

研究成果: ジャーナルへの寄稿学術論文査読

13   !!Link opens in a new tab 被引用数 (Scopus)

抄録

We assessed the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels (DPKs) calculated using the particle and heavy ion transport code system (PHITS) for patient-specific dosimetry in targeted radionuclide treatment (TRT) and compared our data with published data. All mono-energetic and beta-emitting isotope DPKs calculated using PHITS, both in water and compact bone, were in good agreement with those in literature using other MC codes. PHITS provided reliable mono-energetic electron and beta-emitting isotope scaled DPKs for patient-specific dosimetry.

本文言語英語
ページ(範囲)199-203
ページ数5
ジャーナルApplied Radiation and Isotopes
128
DOI
出版ステータス出版済み - 10-2017
外部発表はい