抄録
We assessed the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels (DPKs) calculated using the particle and heavy ion transport code system (PHITS) for patient-specific dosimetry in targeted radionuclide treatment (TRT) and compared our data with published data. All mono-energetic and beta-emitting isotope DPKs calculated using PHITS, both in water and compact bone, were in good agreement with those in literature using other MC codes. PHITS provided reliable mono-energetic electron and beta-emitting isotope scaled DPKs for patient-specific dosimetry.
| 本文言語 | 英語 |
|---|---|
| ページ(範囲) | 199-203 |
| ページ数 | 5 |
| ジャーナル | Applied Radiation and Isotopes |
| 巻 | 128 |
| DOI | |
| 出版ステータス | 出版済み - 10-2017 |