TY - JOUR
T1 - Fluoride-treated rare earth-free magnesium alloy ZK30
T2 - An inert and bioresorbable material for bone fracture treatment devices
AU - Watanabe, Hirotaka
AU - Xu, Wei
AU - Uno, Haruka
AU - Uraya, Yuki
AU - Kugita, Masanori
AU - Komohara, Yoshihiro
AU - Niidome, Takuro
AU - Sasaki, Makoto
AU - Shimizu, Ichiro
AU - Fujita, Nobuyuki
AU - Kawano, Yusuke
N1 - Publisher Copyright:
© 2024 The Authors. Journal of Biomedical Materials Research Part A published by Wiley Periodicals LLC.
PY - 2024/7
Y1 - 2024/7
N2 - Bone fractures represent a common health problem, particularly in an increasingly aging population. Bioresorbable magnesium (Mg) alloy-based implants offer promising alternatives to traditional metallic implants for the treatment of bone fractures because they eliminate the need for implant removal after healing. The Mg-Y-rare-earth (RE)-Zr alloy WE43, designed for orthopedic implants, has received European Conformity mark approval. However, currently, WE43 is not clinically used in certain countries possibly because of concerns related to RE metals. In this study, we investigated the use of a RE-free alloy, namely, Mg-Zn-Zr alloy (ZK30), as an implant for bone fractures. Hydrofluoric acid (HF) treatment was performed to improve the corrosion resistance of ZK30. HF-treated ZK30 (HF-ZK30) exhibited lower corrosion rate and higher biocompatibility than those of WE43 in in vitro experiments. After implanting a rod of HF-ZK30 into the fractured femoral bones of mice, HF-ZK30 held the bones and healed the fracture without deformation. Treatment results of HF-ZK30 were comparable to those of WE43, indicating the potential of HF-ZK30 as a bioresorbable and safe implant for bone repair.
AB - Bone fractures represent a common health problem, particularly in an increasingly aging population. Bioresorbable magnesium (Mg) alloy-based implants offer promising alternatives to traditional metallic implants for the treatment of bone fractures because they eliminate the need for implant removal after healing. The Mg-Y-rare-earth (RE)-Zr alloy WE43, designed for orthopedic implants, has received European Conformity mark approval. However, currently, WE43 is not clinically used in certain countries possibly because of concerns related to RE metals. In this study, we investigated the use of a RE-free alloy, namely, Mg-Zn-Zr alloy (ZK30), as an implant for bone fractures. Hydrofluoric acid (HF) treatment was performed to improve the corrosion resistance of ZK30. HF-treated ZK30 (HF-ZK30) exhibited lower corrosion rate and higher biocompatibility than those of WE43 in in vitro experiments. After implanting a rod of HF-ZK30 into the fractured femoral bones of mice, HF-ZK30 held the bones and healed the fracture without deformation. Treatment results of HF-ZK30 were comparable to those of WE43, indicating the potential of HF-ZK30 as a bioresorbable and safe implant for bone repair.
UR - http://www.scopus.com/inward/record.url?scp=85182685785&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85182685785&partnerID=8YFLogxK
U2 - 10.1002/jbm.a.37673
DO - 10.1002/jbm.a.37673
M3 - Article
AN - SCOPUS:85182685785
SN - 1549-3296
VL - 112
SP - 963
EP - 972
JO - Journal of Biomedical Materials Research - Part A
JF - Journal of Biomedical Materials Research - Part A
IS - 7
ER -