抄録
Background: Clinically insignificant hemolytic anemia is occasionally a complication of prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare complication after central repair for acute aortic dissection. Case presentation: A 42-year-old man had undergone replacement of the ascending aorta and a root repair for type A aortic dissection 6 months previously. Laboratory data showed mild hemolysis 5 months later, and he began to complain of fatigue on exertion. The serum hemoglobin level reduced to 8.6 g/dL, and lactate dehydrogenase levels increased to 3071 IU/L with gross change in urine color, indicating hemoglobinuria. We diagnosed mechanical hemolytic anemia caused by a kinked graft and planned a repeat operation. The kinked graft was resected and graft-graft anastomosis was performed. Postoperatively, the clinical course was uneventful, and the hemolytic anemia completely resolved. Conclusion: We herein report a case of hemolytic anemia caused by kinking of the graft 6 months after acute aortic dissection repair. The diagnosis was swiftly made, and the patient was successfully managed with redo surgery.
| 本文言語 | 英語 |
|---|---|
| 論文番号 | 308 |
| ジャーナル | Journal of Cardiothoracic Surgery |
| 巻 | 17 |
| 号 | 1 |
| DOI | |
| 出版ステータス | 出版済み - 12-2022 |
| 外部発表 | はい |
All Science Journal Classification (ASJC) codes
- 外科
- 呼吸器内科
- 循環器および心血管医学
フィンガープリント
「Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver