メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

High-performance liquid chromatographic assay of anti-inflammatory drugs incorporated in gel ointments Separation and stability testing

  • Keiko Yamamura
  • , Jun Ichiro Yamada
  • , Toshihisa Yotsuyanagi

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

抄録

High-performance liquid chromatographic determinations of gabexate mesilate (FOY) prostaglandin E1 (PGE1, PGE1-α-cyclodextrin (PGE1,-CD), prednisolone (PD) and butyl flufenamate (BF) incorporated in gel ointment were investigated. The gel ointment is composed of a carboxy vinyl polymer (1.3%, w/w) and a large amount of an aqueous organic solvent. A methanol extraction system offered simultaneous advantages of the removal of the polymer and the recovery of active ingredients from the gel phase. The recoveries of the drugs were 100%. The stabilities of PGE1, PGE1-CD, FOY, PD and BF incorporated in gel ointment, stored at 5, 25 and 40°C for up to 90 days, were investigated.

本文言語英語
ページ(範囲)383-388
ページ数6
ジャーナルJournal of Chromatography A
巻331
号C
DOI
出版ステータス出版済み - 1985
外部発表はい

All Science Journal Classification (ASJC) codes

  • 分析化学
  • 生化学
  • 有機化学

フィンガープリント

「High-performance liquid chromatographic assay of anti-inflammatory drugs incorporated in gel ointments Separation and stability testing」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル