© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact [email protected] for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact [email protected]. This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/pages/standard-publication-reuse-rights)
PY - 2026/7
Y1 - 2026/7
N2 - Recent Boron neutron capture therapy (BNCT) has shifted to accelerator-based systems. One of them is a compact neutron generator developed using silicon carbide (SiC) semiconductors by Fukushima SiC Applied Technology Co. However, neutron penetration remains a critical challenge for treating deep-seated tumors. This study investigated the potential of neutron sieve therapy, originally developed to enhance the depth dose distribution in X-ray therapy, to improve BNCT dose distribution via Monte Carlo simulations based on the Fukushima SiC BNCT system. Dose distribution changes were investigated using polyethylene and 6LiF-plastic in block and sieve shapes. The results show that the maximum thermal neutron fluence depth was shallower (deeper) with polyethylene (6LiF-plastic) filters. The sieve filter moderately altered the dose distribution compared to the block filter due to density differences. The maximum dose point shifted 8 mm deeper using a sieve filter composed of 6LiF-plastic and polyethylene, with a 5.5% increase at 20 mm depth in neutron fluence at the same skin dose.
AB - Recent Boron neutron capture therapy (BNCT) has shifted to accelerator-based systems. One of them is a compact neutron generator developed using silicon carbide (SiC) semiconductors by Fukushima SiC Applied Technology Co. However, neutron penetration remains a critical challenge for treating deep-seated tumors. This study investigated the potential of neutron sieve therapy, originally developed to enhance the depth dose distribution in X-ray therapy, to improve BNCT dose distribution via Monte Carlo simulations based on the Fukushima SiC BNCT system. Dose distribution changes were investigated using polyethylene and 6LiF-plastic in block and sieve shapes. The results show that the maximum thermal neutron fluence depth was shallower (deeper) with polyethylene (6LiF-plastic) filters. The sieve filter moderately altered the dose distribution compared to the block filter due to density differences. The maximum dose point shifted 8 mm deeper using a sieve filter composed of 6LiF-plastic and polyethylene, with a 5.5% increase at 20 mm depth in neutron fluence at the same skin dose.
UR - https://www.scopus.com/pages/publications/105043861581
UR - https://www.scopus.com/pages/publications/105043861581#tab=citedBy
U2 - 10.1093/rpd/ncag018
DO - 10.1093/rpd/ncag018
M3 - Article
C2 - 41770639
AN - SCOPUS:105043861581
SN - 0144-8420
VL - 202
SP - 845
EP - 849
JO - Radiation protection dosimetry
JF - Radiation protection dosimetry
IS - 11
ER -