メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Impella 5.0 for Cardiogenic Shock After Thrombectomy in a Patient With Intraventricular Thrombosis

  • Yuki Kimura
  • , Toru Kondo
  • , Masato Mutsuga
  • , Ryota Morimoto
  • , Shingo Kazama
  • , Naoki Shibata
  • , Hideo Oishi
  • , Yoshihito Arao
  • , Tasuku Kuwayama
  • , Hiroo Kato
  • , Shogo Yamaguchi
  • , Hiroaki Hiraiwa
  • , Takahiro Okumura
  • , Kazuro Fujimoto
  • , Akihiko Usui
  • , Toyoaki Murohara

研究成果: ジャーナルへの寄稿学術論文査読

抄録

A 43-year-old man was admitted to a referring hospital for cardiogenic shock caused by dilated cardiomyopathy. Intra-aortic balloon pump and percutaneous venoarterial extracorporeal membrane oxygenation (VA-ECMO) were started initially; however, a thrombus was detected in the left ventricle. After transfer to our institution, we performed thrombectomy through minithoracotomy. Subsequently, an Impella 5.0 device was inserted via the left subclavian artery. His cardiac function gradually improved, and both VA-ECMO and the Impella 5.0 could be weaned off. He was discharged without any thromboembolic event. Impella insertion with thrombectomy was possible, minimally invasive, and effective for a patient with intraventricular thrombosis associated with VA-ECMO.

本文言語英語
ページ(範囲)1690.e13-1690.e15
ジャーナルCanadian Journal of Cardiology
36
10
DOI
出版ステータス出版済み - 10-2020
外部発表はい

All Science Journal Classification (ASJC) codes

  • 循環器および心血管医学

フィンガープリント

「Impella 5.0 for Cardiogenic Shock After Thrombectomy in a Patient With Intraventricular Thrombosis」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル