TY - JOUR
T1 - Incidence and risk factors for peripheral intravenous catheter failure in Japanese neonatal intensive care units and growing care units
T2 - a multicenter observational study
AU - Yamamoto, Shun
AU - Murayama, Ryoko
N1 - Publisher Copyright:
Copyright © 2026 Shun Yamamoto, MHS, RN et al. This is an Open access article distributed under the Terms of Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
PY - 2026
Y1 - 2026
N2 - Objectives: Peripheral intravenous catheters (PIVCs) are used in neonatal intensive care units (NICUs) and growing care units (GCUs). However, neonates/infants in these units frequently experience catheter failure (CF) because of complications, such as extravasation and phlebitis. Nonetheless, data on PIVCs from Japan remain limited. Therefore, this study aimed to investigate the use of infusion catheters and the incidence, characteristics, and risk factors of PIVC-related catheter failure in Japanese NICUs and GCUs. Methods: This study was conducted between August 2024 and February 2025 using cross-sectional and prospective surveys. Data from 600 hospitalized neonates/infants and 259 PIVC cases were analyzed. CF was defined as unplanned catheter removal before the completion of therapy owing to loss of function or an inability to administer fluids. Results: Overall, 48.0% of neonates/infants had infusion catheters. The incidence proportion of CF was 47.1%, with an incidence density of 173.1/1,000 catheter-days. Extravasation was the most frequently identified cause of CF (95.9%), and swelling and leaking were primary symptoms. Multivariate Cox regression showed that gestational age (hazard ratio=0.96, p=.03) and infusion flow volume at the time of PIVC removal (hazard ratio=1.28/1 mL/h, p<.01) were significant risk factors. Long PIVCs had significantly longer dwell times than PIVCs (log-rank p=.01). Conclusions: CF is highly prevalent in Japanese infants in NICUs/GCUs, with a rate similar to that reported internationally. Long PIVCs may help extend the catheter dwell times. These findings highlight the need for standardized prevention strategies and improved catheter management protocols.
AB - Objectives: Peripheral intravenous catheters (PIVCs) are used in neonatal intensive care units (NICUs) and growing care units (GCUs). However, neonates/infants in these units frequently experience catheter failure (CF) because of complications, such as extravasation and phlebitis. Nonetheless, data on PIVCs from Japan remain limited. Therefore, this study aimed to investigate the use of infusion catheters and the incidence, characteristics, and risk factors of PIVC-related catheter failure in Japanese NICUs and GCUs. Methods: This study was conducted between August 2024 and February 2025 using cross-sectional and prospective surveys. Data from 600 hospitalized neonates/infants and 259 PIVC cases were analyzed. CF was defined as unplanned catheter removal before the completion of therapy owing to loss of function or an inability to administer fluids. Results: Overall, 48.0% of neonates/infants had infusion catheters. The incidence proportion of CF was 47.1%, with an incidence density of 173.1/1,000 catheter-days. Extravasation was the most frequently identified cause of CF (95.9%), and swelling and leaking were primary symptoms. Multivariate Cox regression showed that gestational age (hazard ratio=0.96, p=.03) and infusion flow volume at the time of PIVC removal (hazard ratio=1.28/1 mL/h, p<.01) were significant risk factors. Long PIVCs had significantly longer dwell times than PIVCs (log-rank p=.01). Conclusions: CF is highly prevalent in Japanese infants in NICUs/GCUs, with a rate similar to that reported internationally. Long PIVCs may help extend the catheter dwell times. These findings highlight the need for standardized prevention strategies and improved catheter management protocols.
KW - Catheter failure
KW - Japan
KW - Multicenter observational study
KW - NICU
KW - Peripheral intravenous catheter
UR - https://www.scopus.com/pages/publications/105048170879
UR - https://www.scopus.com/pages/publications/105048170879#tab=citedBy
U2 - 10.20407/fmj.2025-027
DO - 10.20407/fmj.2025-027
M3 - Article
AN - SCOPUS:105048170879
SN - 2189-7247
VL - 12
SP - 135
EP - 142
JO - Fujita Medical Journal
JF - Fujita Medical Journal
IS - 2
ER -