InFOCμS hard X-ray imaging telescope

J. Tueller, H. A. Krimm, T. Okajima, S. D. Barthelmy, S. M. Owens, P. J. Serlemitsos, Y. Soong, K. W. Chan, Y. Ogasaka, R. Shibata, K. Tamura, A. Furuzawa, Y. Tawara, H. Kunieda, K. Yamashita

研究成果: Article

16 引用 (Scopus)

抄録

InFOCμS is a new generation balloon-borne hard X-ray telescope with focusing optics and spectroscopy. We had a successful 22.5-hour flight from Fort Sumner, NM on September 16,17, 2004. In this paper, we present the performance of the hard X-ray telescope, which consists of a depth-graded platinum/carbon multilayer mirror and a CdZnTe detector. The telescope has an effective area of 49 cm2 at 30 keV, an angular resolution of 2.4 arcmin (HPD), and a field of view of 11 arcmin (FWHM) depending on energies. The CdZnTe detector is configured with a 12 × 12 segmented array of detector pixels. The pixels are 2 mm square, and are placed on 2.1 mm centers. An averaged energy resolution is 4.4 keV at 60 keV and its standard deviation is 0.36 keV over 128 pixels. The detector is surrounded by a 3-cm thick CsI anti coincidence shield to reduce background from particles and photons not incident along the mirror focal direction. The inflight background is 2.9 × 10-4 cts cm -2 sec-1 keV-1 in the 20-50 keV band.

元の言語English
ページ(範囲)121-129
ページ数9
ジャーナルExperimental Astronomy
20
発行部数1-3
DOI
出版物ステータスPublished - 01-12-2005
外部発表Yes

Fingerprint

telescopes
pixel
pixels
detectors
x rays
mirrors
balloons
field of view
angular resolution
platinum
energy
shield
standard deviation
spectroscopy
flight
optics
detector
carbon
photons
particle

All Science Journal Classification (ASJC) codes

  • Astronomy and Astrophysics
  • Space and Planetary Science

これを引用

Tueller, J., Krimm, H. A., Okajima, T., Barthelmy, S. D., Owens, S. M., Serlemitsos, P. J., ... Yamashita, K. (2005). InFOCμS hard X-ray imaging telescope. Experimental Astronomy, 20(1-3), 121-129. https://doi.org/10.1007/s10686-006-9028-3
Tueller, J. ; Krimm, H. A. ; Okajima, T. ; Barthelmy, S. D. ; Owens, S. M. ; Serlemitsos, P. J. ; Soong, Y. ; Chan, K. W. ; Ogasaka, Y. ; Shibata, R. ; Tamura, K. ; Furuzawa, A. ; Tawara, Y. ; Kunieda, H. ; Yamashita, K. / InFOCμS hard X-ray imaging telescope. :: Experimental Astronomy. 2005 ; 巻 20, 番号 1-3. pp. 121-129.
@article{4cd5e9e6d55c4454897fca407a6a3a47,
title = "InFOCμS hard X-ray imaging telescope",
abstract = "InFOCμS is a new generation balloon-borne hard X-ray telescope with focusing optics and spectroscopy. We had a successful 22.5-hour flight from Fort Sumner, NM on September 16,17, 2004. In this paper, we present the performance of the hard X-ray telescope, which consists of a depth-graded platinum/carbon multilayer mirror and a CdZnTe detector. The telescope has an effective area of 49 cm2 at 30 keV, an angular resolution of 2.4 arcmin (HPD), and a field of view of 11 arcmin (FWHM) depending on energies. The CdZnTe detector is configured with a 12 × 12 segmented array of detector pixels. The pixels are 2 mm square, and are placed on 2.1 mm centers. An averaged energy resolution is 4.4 keV at 60 keV and its standard deviation is 0.36 keV over 128 pixels. The detector is surrounded by a 3-cm thick CsI anti coincidence shield to reduce background from particles and photons not incident along the mirror focal direction. The inflight background is 2.9 × 10-4 cts cm -2 sec-1 keV-1 in the 20-50 keV band.",
author = "J. Tueller and Krimm, {H. A.} and T. Okajima and Barthelmy, {S. D.} and Owens, {S. M.} and Serlemitsos, {P. J.} and Y. Soong and Chan, {K. W.} and Y. Ogasaka and R. Shibata and K. Tamura and A. Furuzawa and Y. Tawara and H. Kunieda and K. Yamashita",
year = "2005",
month = "12",
day = "1",
doi = "10.1007/s10686-006-9028-3",
language = "English",
volume = "20",
pages = "121--129",
journal = "Experimental Astronomy",
issn = "0922-6435",
publisher = "Springer Netherlands",
number = "1-3",

}

Tueller, J, Krimm, HA, Okajima, T, Barthelmy, SD, Owens, SM, Serlemitsos, PJ, Soong, Y, Chan, KW, Ogasaka, Y, Shibata, R, Tamura, K, Furuzawa, A, Tawara, Y, Kunieda, H & Yamashita, K 2005, 'InFOCμS hard X-ray imaging telescope', Experimental Astronomy, 巻. 20, 番号 1-3, pp. 121-129. https://doi.org/10.1007/s10686-006-9028-3

InFOCμS hard X-ray imaging telescope. / Tueller, J.; Krimm, H. A.; Okajima, T.; Barthelmy, S. D.; Owens, S. M.; Serlemitsos, P. J.; Soong, Y.; Chan, K. W.; Ogasaka, Y.; Shibata, R.; Tamura, K.; Furuzawa, A.; Tawara, Y.; Kunieda, H.; Yamashita, K.

:: Experimental Astronomy, 巻 20, 番号 1-3, 01.12.2005, p. 121-129.

研究成果: Article

TY - JOUR

T1 - InFOCμS hard X-ray imaging telescope

AU - Tueller, J.

AU - Krimm, H. A.

AU - Okajima, T.

AU - Barthelmy, S. D.

AU - Owens, S. M.

AU - Serlemitsos, P. J.

AU - Soong, Y.

AU - Chan, K. W.

AU - Ogasaka, Y.

AU - Shibata, R.

AU - Tamura, K.

AU - Furuzawa, A.

AU - Tawara, Y.

AU - Kunieda, H.

AU - Yamashita, K.

PY - 2005/12/1

Y1 - 2005/12/1

N2 - InFOCμS is a new generation balloon-borne hard X-ray telescope with focusing optics and spectroscopy. We had a successful 22.5-hour flight from Fort Sumner, NM on September 16,17, 2004. In this paper, we present the performance of the hard X-ray telescope, which consists of a depth-graded platinum/carbon multilayer mirror and a CdZnTe detector. The telescope has an effective area of 49 cm2 at 30 keV, an angular resolution of 2.4 arcmin (HPD), and a field of view of 11 arcmin (FWHM) depending on energies. The CdZnTe detector is configured with a 12 × 12 segmented array of detector pixels. The pixels are 2 mm square, and are placed on 2.1 mm centers. An averaged energy resolution is 4.4 keV at 60 keV and its standard deviation is 0.36 keV over 128 pixels. The detector is surrounded by a 3-cm thick CsI anti coincidence shield to reduce background from particles and photons not incident along the mirror focal direction. The inflight background is 2.9 × 10-4 cts cm -2 sec-1 keV-1 in the 20-50 keV band.

AB - InFOCμS is a new generation balloon-borne hard X-ray telescope with focusing optics and spectroscopy. We had a successful 22.5-hour flight from Fort Sumner, NM on September 16,17, 2004. In this paper, we present the performance of the hard X-ray telescope, which consists of a depth-graded platinum/carbon multilayer mirror and a CdZnTe detector. The telescope has an effective area of 49 cm2 at 30 keV, an angular resolution of 2.4 arcmin (HPD), and a field of view of 11 arcmin (FWHM) depending on energies. The CdZnTe detector is configured with a 12 × 12 segmented array of detector pixels. The pixels are 2 mm square, and are placed on 2.1 mm centers. An averaged energy resolution is 4.4 keV at 60 keV and its standard deviation is 0.36 keV over 128 pixels. The detector is surrounded by a 3-cm thick CsI anti coincidence shield to reduce background from particles and photons not incident along the mirror focal direction. The inflight background is 2.9 × 10-4 cts cm -2 sec-1 keV-1 in the 20-50 keV band.

UR - http://www.scopus.com/inward/record.url?scp=33751094036&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751094036&partnerID=8YFLogxK

U2 - 10.1007/s10686-006-9028-3

DO - 10.1007/s10686-006-9028-3

M3 - Article

AN - SCOPUS:33751094036

VL - 20

SP - 121

EP - 129

JO - Experimental Astronomy

JF - Experimental Astronomy

SN - 0922-6435

IS - 1-3

ER -

Tueller J, Krimm HA, Okajima T, Barthelmy SD, Owens SM, Serlemitsos PJ その他. InFOCμS hard X-ray imaging telescope. Experimental Astronomy. 2005 12 1;20(1-3):121-129. https://doi.org/10.1007/s10686-006-9028-3