メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Inspection technique of foreign objects in BGA solder joint using oblique X-ray computed tomography

  • Kenji Noguchi
  • , Atsushi Teramoto
  • , Muneo Yamada
  • , Takayuki Murakoshi

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Foreign objects in a solder joint could deteriorate the joint strength when mounting BGA (Ball Grid Array) packages or CSP (Chip Scale Package) on printed circuit boards. However, foreign objects within solder bumps are not detected by optical inspection which has been used widely. Recently, X-ray computed tomography (CT) for the inspection of printed circuit boards has been developed. X-ray CT visualizes the foreign objects inside a solder joint. If they are automatically detected, higher soldering quality is expected. In this paper, we propose an automated detection method of foreign objects in solder joints using CT slice images. In the method, some characteristic values are identified which show the solder joint deformation. In the experiments, actual mounting substrates involving solder bumps contaminated by foreign objects were checked using the proposed method. The detection accuracy rate reached 98.9%, which clearly indicates that the proposed method is useful in practice.

本文言語英語
ページ(範囲)63-70
ページ数8
ジャーナルJournal of Japan Institute of Electronics Packaging
13
1
DOI
出版ステータス出版済み - 01-2010

All Science Journal Classification (ASJC) codes

  • 電子工学および電気工学

フィンガープリント

「Inspection technique of foreign objects in BGA solder joint using oblique X-ray computed tomography」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル