TY - JOUR
T1 - Mechanical circulatory support devices for elective percutaneous coronary interventions
T2 - novel insights from the Japanese nationwide J-PCI registry
AU - Japanese Association of Cardiovascular Intervention and Therapeutics
AU - Muramatsu, Takashi
AU - Inohara, Taku
AU - Kohsaka, Shun
AU - Yamaji, Kyohei
AU - Ishii, Hideki
AU - Shinke, Toshiro
AU - Toriya, Takuo
AU - Yoshiki, Yu
AU - Ozaki, Yukio
AU - Ando, Hirohiko
AU - Amano, Tetsuya
AU - Nakamura, Masato
AU - Ikari, Yuji
N1 - Publisher Copyright:
© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology.
PY - 2022/7/1
Y1 - 2022/7/1
N2 - Aims We examined in-hospital outcomes of patients that required mechanical circulatory support (MCS), such as intra-aortic balloon pumping (IABP), Impella®, or veno-arterial extracorporeal membrane oxygenation (VA-ECMO), for elective percutaneous coronary interventions (PCIs). Methods and results The J-PCI is a prospective Japanese nationwide multicentre registry sponsored by the Japanese Association of Cardiovascular Intervention and Therapeutics (CVIT) and designed to collect clinical variables and in-hospital outcome data on consecutive patients undergoing PCI. Of the 253 228 patients registered between January 2018 and December 2018, 1627 patients (0.6%) undergoing elective PCI under MCS at 551 sites were analyzed. The mean age of the patients was 74 years, and 25.2% of the patients were females. Multivessel disease and left main disease were observed in 59.0% and 19.7% of the patients, respectively. Majority of patients were treated with IABP alone (86.2%), followed by IABP plus VA-ECMO (6.0%) and Impella alone (3.9%). In-hospital mortality was reported in 134 patients (8.2%). Cardiac death was more common than non-cardiac death (6.8% vs. 1.5%). About 34.6% of the patients receiving VA-ECMO died during hospitalization, whereas 7.2% and 5.3% of patients receiving Impella and IABP died, respectively (P < 0.01). The proportion of patients with VA-ECMO or Impella who had major bleeding requiring blood transfusion was higher than that of patients with IABP (14.1% vs. 13.0% vs. 2.8%). Conclusion In the setting of elective PCI, in-hospital mortality of patients requiring MCS was considerably high. VA-ECMO or Impella was associated with a higher risk of major bleeding than IABP.
AB - Aims We examined in-hospital outcomes of patients that required mechanical circulatory support (MCS), such as intra-aortic balloon pumping (IABP), Impella®, or veno-arterial extracorporeal membrane oxygenation (VA-ECMO), for elective percutaneous coronary interventions (PCIs). Methods and results The J-PCI is a prospective Japanese nationwide multicentre registry sponsored by the Japanese Association of Cardiovascular Intervention and Therapeutics (CVIT) and designed to collect clinical variables and in-hospital outcome data on consecutive patients undergoing PCI. Of the 253 228 patients registered between January 2018 and December 2018, 1627 patients (0.6%) undergoing elective PCI under MCS at 551 sites were analyzed. The mean age of the patients was 74 years, and 25.2% of the patients were females. Multivessel disease and left main disease were observed in 59.0% and 19.7% of the patients, respectively. Majority of patients were treated with IABP alone (86.2%), followed by IABP plus VA-ECMO (6.0%) and Impella alone (3.9%). In-hospital mortality was reported in 134 patients (8.2%). Cardiac death was more common than non-cardiac death (6.8% vs. 1.5%). About 34.6% of the patients receiving VA-ECMO died during hospitalization, whereas 7.2% and 5.3% of patients receiving Impella and IABP died, respectively (P < 0.01). The proportion of patients with VA-ECMO or Impella who had major bleeding requiring blood transfusion was higher than that of patients with IABP (14.1% vs. 13.0% vs. 2.8%). Conclusion In the setting of elective PCI, in-hospital mortality of patients requiring MCS was considerably high. VA-ECMO or Impella was associated with a higher risk of major bleeding than IABP.
UR - http://www.scopus.com/inward/record.url?scp=85154036868&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85154036868&partnerID=8YFLogxK
U2 - 10.1093/ehjopen/oeac041
DO - 10.1093/ehjopen/oeac041
M3 - Article
AN - SCOPUS:85154036868
SN - 2752-4191
VL - 2
JO - European Heart Journal Open
JF - European Heart Journal Open
IS - 4
M1 - oeac041
ER -