抄録
A 66-year-old woman developed marked haemolytic anaemia 2 years after total aortic arch replacement using a branched Dacron graft. Echocardiography confirmed bicuspid aortic valve stenosis. A four-dimensional flow magnetic resonance imaging revealed a jet flow arising from the aortic valve along with the vortex and turbulent flow inside the kinked prosthetic graft at the ascending aorta. She underwent a reoperation to replace the aortic valve and correct the kinking. The estimated energy loss after intervention was relieved to 2.9 mJ/cardiac cycle from 4.3 mJ/cardiac cycle before intervention. The patient's anaemia resolved immediately after the reoperation.
本文言語 | 英語 |
---|---|
ページ(範囲) | 813-814 |
ページ数 | 2 |
ジャーナル | European Journal of Cardio-thoracic Surgery |
巻 | 56 |
号 | 4 |
DOI | |
出版ステータス | 出版済み - 01-10-2019 |
外部発表 | はい |
All Science Journal Classification (ASJC) codes
- 外科
- 呼吸器内科
- 循環器および心血管医学