メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Microvascular obstruction on delayed enhancement cardiac magnetic resonance imaging after acute myocardial infarction, compared with myocardial 201Tl and 123I-BMIPP dual SPECT findings

  • Hiroaki Mori
  • , Satoshi Isobe
  • , Shinichi Sakai
  • , Takashi Yamada
  • , Naoki Watanabe
  • , Manabu Miura
  • , Yasuhiro Uchida
  • , Masaaki Kanashiro
  • , Satoshi Ichimiya
  • , Takahiro Okumura
  • , Toyoaki Murohara

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Background The hypo-enhanced regions within the hyper-enhanced infarct areas detected by cardiac magnetic resonance (CMR) imaging reflect microvascular obstruction (MO) after acute myocardial infarction (AMI). The combined myocardial thallium-201 (201Tl)/iodine-123-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (123I-BMIPP) dual single-photon emission computed tomography (SPECT) is a useful tool for detecting myocardial reversibility after AMI. We evaluated whether MO could be an early predictor of irreversible myocardial damage in comparison with 201Tl and 123I-BMIPP dual SPECT findings in AMI patients. Methods Sixty-two patients with initial AMI who successfully underwent coronary revascularization were enrolled. MO was defined by CMR imaging. Patients were divided into 2 groups as follows: MO group (n = 32) and non-MO group (n = 30). Scintigraphic defect scores were calculated using a 17-segment model with a 5-point scoring system. The mismatch score (MMS) was calculated as follows: the total sum of (Σ) 123I-BMIPP defect score minus Σ201Tl defect score. The percentage mismatch score (%MMS) was calculated as follows: MMS/(Σ123I-BMIPP score) × 100 (%). Results The percentage infarct size (%IS) was significantly greater in the MO group than in the non-MO group (32.2 ± 13.8% vs. 18.3 ± 12.1%, p < 0.001). The %MMS significantly correlated with the %IS and the percentage MO (r = -0.26, p = 0.03; r = -0.45, p < 0.001, respectively). The %MMS was significantly greater in the non-MO group than in the MO group (45.4 ± 42.4% vs. 13.3 ± 28.0%, p = 0.001), and was an independent predictor for MO (OR 0.97, 95%CI 0.94-0.99, p = 0.02). Conclusions Our results reconfirm that, in comparison with myocardial dual scintigraphy, MO is an important structural abnormality. CMR imaging is useful for the early detection of irreversible myocardial damage after AMI.

本文言語英語
ページ(範囲)1516-1524
ページ数9
ジャーナルEuropean journal of radiology
84
8
DOI
出版ステータス出版済み - 01-08-2015
外部発表はい

All Science Journal Classification (ASJC) codes

  • 放射線学、核医学およびイメージング

フィンガープリント

「Microvascular obstruction on delayed enhancement cardiac magnetic resonance imaging after acute myocardial infarction, compared with myocardial 201Tl and 123I-BMIPP dual SPECT findings」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル