TY - JOUR
T1 - Movement of the eustachian tube during sniffing in patients with patulous eustachian tube
T2 - Evaluation using a 320-row area detector CT scanner
AU - Yoshioka, Satoshi
AU - Naito, Kensei
AU - Fujii, Naoko
AU - Katada, Kazuhiro
PY - 2013/7
Y1 - 2013/7
N2 - OBJECTIVE: The Eustachian tube is difficult to evaluate because it is located deep in the head. However, the introduction of 320-row area detector CT has made it possible to evaluate this region. In the present study, movement of the Eustachian tube during sniffing was visualized using area detector CT in patients with patulous Eustachian tube. METHODS: Four patients with patulous Eustachian tube were examined using an area detector CT scanner (Aquilion ONE, Toshiba). This scanner supports 320-row scanning of 0.5-mm slices at up to 0.275 s/rot., eliminating temporal mismatch between various parts of the acquired images and permitting 4-dimensional CT (4DCT) images to be obtained by continuous scanning. The scan conditions were 120 kV, 120 to 150 mA, 0.5 mm × 280 to 320 slices, and 0.35 seconds per rotation × 9 rotations. The patient was seated on a reclining chair tilted to 45 degrees and was instructed to sniff during continuous scanning. Images of the Eustachian tube were generated at 0.1-second intervals. CONCLUSION: At the start of sniffing, the cartilaginous portion of the Eustachian tube closed from the isthmus toward the pharynx. The starting point differed from patient to patient. In patients with patulous Eustachian tube, sniffing (an unconscious habit that helps to relieve ear discomfort) is an important factor in the development of middle ear diseases. We have successfully depicted this event for the first time, demonstrating various patterns of Eustachian tube closure during sniffing in patients with patulous Eustachian tube. This method may be useful for evaluating Eustachian tube dysfunction.
AB - OBJECTIVE: The Eustachian tube is difficult to evaluate because it is located deep in the head. However, the introduction of 320-row area detector CT has made it possible to evaluate this region. In the present study, movement of the Eustachian tube during sniffing was visualized using area detector CT in patients with patulous Eustachian tube. METHODS: Four patients with patulous Eustachian tube were examined using an area detector CT scanner (Aquilion ONE, Toshiba). This scanner supports 320-row scanning of 0.5-mm slices at up to 0.275 s/rot., eliminating temporal mismatch between various parts of the acquired images and permitting 4-dimensional CT (4DCT) images to be obtained by continuous scanning. The scan conditions were 120 kV, 120 to 150 mA, 0.5 mm × 280 to 320 slices, and 0.35 seconds per rotation × 9 rotations. The patient was seated on a reclining chair tilted to 45 degrees and was instructed to sniff during continuous scanning. Images of the Eustachian tube were generated at 0.1-second intervals. CONCLUSION: At the start of sniffing, the cartilaginous portion of the Eustachian tube closed from the isthmus toward the pharynx. The starting point differed from patient to patient. In patients with patulous Eustachian tube, sniffing (an unconscious habit that helps to relieve ear discomfort) is an important factor in the development of middle ear diseases. We have successfully depicted this event for the first time, demonstrating various patterns of Eustachian tube closure during sniffing in patients with patulous Eustachian tube. This method may be useful for evaluating Eustachian tube dysfunction.
UR - http://www.scopus.com/inward/record.url?scp=84880923808&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880923808&partnerID=8YFLogxK
U2 - 10.1097/MAO.0b013e31827d0963
DO - 10.1097/MAO.0b013e31827d0963
M3 - Article
C2 - 23303173
AN - SCOPUS:84880923808
SN - 1531-7129
VL - 34
SP - 877
EP - 883
JO - Otology and Neurotology
JF - Otology and Neurotology
IS - 5
ER -