抄録
For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.
元の言語 | English |
---|---|
ページ(範囲) | 861-866 |
ページ数 | 6 |
ジャーナル | Nuclear Medicine Communications |
巻 | 13 |
発行部数 | 12 |
出版物ステータス | Published - 01-01-1992 |
Fingerprint
All Science Journal Classification (ASJC) codes
- Radiology Nuclear Medicine and imaging
これを引用
}
Neuroanatomical localization for clinical spect perfusion brain imaging : A practical proportional grid method. / Ichise, M.; Toyama, H.; Vines, D. C.; Chung, D. G.; Kirsh, J. C.
:: Nuclear Medicine Communications, 巻 13, 番号 12, 01.01.1992, p. 861-866.研究成果: Article
TY - JOUR
T1 - Neuroanatomical localization for clinical spect perfusion brain imaging
T2 - A practical proportional grid method
AU - Ichise, M.
AU - Toyama, H.
AU - Vines, D. C.
AU - Chung, D. G.
AU - Kirsh, J. C.
PY - 1992/1/1
Y1 - 1992/1/1
N2 - For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.
AB - For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.
UR - http://www.scopus.com/inward/record.url?scp=0027054421&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027054421&partnerID=8YFLogxK
M3 - Article
C2 - 1465268
AN - SCOPUS:0027054421
VL - 13
SP - 861
EP - 866
JO - Nuclear Medicine Communications
JF - Nuclear Medicine Communications
SN - 0143-3636
IS - 12
ER -