Neuroanatomical localization for clinical spect perfusion brain imaging: A practical proportional grid method

M. Ichise, H. Toyama, D. C. Vines, D. G. Chung, J. C. Kirsh

研究成果: Article

12 引用 (Scopus)

抄録

For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.

元の言語English
ページ(範囲)861-866
ページ数6
ジャーナルNuclear Medicine Communications
13
発行部数12
出版物ステータスPublished - 01-01-1992

Fingerprint

Perfusion Imaging
Oximes
Neuroimaging
Amines
Single-Photon Emission-Computed Tomography
Gamma Cameras
Brain
Photons
Software

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

これを引用

Ichise, M. ; Toyama, H. ; Vines, D. C. ; Chung, D. G. ; Kirsh, J. C. / Neuroanatomical localization for clinical spect perfusion brain imaging : A practical proportional grid method. :: Nuclear Medicine Communications. 1992 ; 巻 13, 番号 12. pp. 861-866.
@article{36dc2bcb6c9c4747adcec534e8b73e18,
title = "Neuroanatomical localization for clinical spect perfusion brain imaging: A practical proportional grid method",
abstract = "For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.",
author = "M. Ichise and H. Toyama and Vines, {D. C.} and Chung, {D. G.} and Kirsh, {J. C.}",
year = "1992",
month = "1",
day = "1",
language = "English",
volume = "13",
pages = "861--866",
journal = "Nuclear Medicine Communications",
issn = "0143-3636",
publisher = "Lippincott Williams and Wilkins",
number = "12",

}

Neuroanatomical localization for clinical spect perfusion brain imaging : A practical proportional grid method. / Ichise, M.; Toyama, H.; Vines, D. C.; Chung, D. G.; Kirsh, J. C.

:: Nuclear Medicine Communications, 巻 13, 番号 12, 01.01.1992, p. 861-866.

研究成果: Article

TY - JOUR

T1 - Neuroanatomical localization for clinical spect perfusion brain imaging

T2 - A practical proportional grid method

AU - Ichise, M.

AU - Toyama, H.

AU - Vines, D. C.

AU - Chung, D. G.

AU - Kirsh, J. C.

PY - 1992/1/1

Y1 - 1992/1/1

N2 - For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.

AB - For the purpose of facilitating anatomical localization in interpretation of99Tcm-hexamethylpropylene- amine oxime (HMPAO) brain single photon emission tomographic (SPECT) scans, a stereotaxic proportional grid system was applied in the form of an interactive computer program. This method takes advantage of a rotating gamma camera system which permits planar scout imaging for the determination of anatomical reference lines, and standardization of tomographic slices for brain size. Using measurements made on a lateral planar HMPAO image, proportional grids were constructed onto standardized transaxial images. This method was implemented for 33 clinical HMPAO SPECT studies. It required less than 15 min of an operator's time. This simple and practical neuroanatomical localization technique can be instrumental as an aid to the interpretation of routine clinical HMPAO SPECT images.

UR - http://www.scopus.com/inward/record.url?scp=0027054421&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027054421&partnerID=8YFLogxK

M3 - Article

C2 - 1465268

AN - SCOPUS:0027054421

VL - 13

SP - 861

EP - 866

JO - Nuclear Medicine Communications

JF - Nuclear Medicine Communications

SN - 0143-3636

IS - 12

ER -