TY - JOUR
T1 - New method of measuring presampling MTF by fourier transform of square-wave chart image
AU - Itikawa, Katuhiro
AU - Kunitomo, Hiroshi
AU - Sakurai, Takahiro
AU - Ohashi, Kazuya
AU - Sugiyama, Masayuki
AU - Miyati, Tosiaki
AU - Fujita, Hiroshi
PY - 2002
Y1 - 2002
N2 - We developed an easy method of measuring the presampling modulation transfer function (MTF) using the square wave chart in digital radiography. In this method, the presampling MTF is measured by Fourier transform of image data of the square wave chart. When Fourier analysis of the sampling data of a square wave is carried out, it is generally difficult to find the starting point and terminal point of the periodic data that should be extracted because of an insufficient number of data. To solve this problem, interpolated data were calculated by using a window function of the frequency domain. The aliasing error was avoided using a characteristic such that the square wave has discrete frequency components. The accuracy of this method was investigated by computer simulation study. Actual measurement of the presampling MTF by this method was also performed with a CR system. These studies indicated the effectiveness of our proposed method in terms of accuracy and ease of use.
AB - We developed an easy method of measuring the presampling modulation transfer function (MTF) using the square wave chart in digital radiography. In this method, the presampling MTF is measured by Fourier transform of image data of the square wave chart. When Fourier analysis of the sampling data of a square wave is carried out, it is generally difficult to find the starting point and terminal point of the periodic data that should be extracted because of an insufficient number of data. To solve this problem, interpolated data were calculated by using a window function of the frequency domain. The aliasing error was avoided using a characteristic such that the square wave has discrete frequency components. The accuracy of this method was investigated by computer simulation study. Actual measurement of the presampling MTF by this method was also performed with a CR system. These studies indicated the effectiveness of our proposed method in terms of accuracy and ease of use.
UR - http://www.scopus.com/inward/record.url?scp=0036770017&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036770017&partnerID=8YFLogxK
U2 - 10.6009/jjrt.KJ00001364806
DO - 10.6009/jjrt.KJ00001364806
M3 - Article
C2 - 12520222
AN - SCOPUS:0036770017
SN - 0369-4305
VL - 58
SP - 1261
EP - 1267
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
IS - 9
ER -