メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Quantification of myocardial blood flow using the combination of bolus tracking and time-registered helical multidetector CT angiography during adenosine stress

  • Takashi Ichihara
  • , Richard T. George
  • , Richard Mather
  • , Caterina Silva
  • , Joao A.C. Lima
  • , Albert C. Lardo

研究成果: 書籍/レポート タイプへの寄稿 › 会議への寄与

抄録

The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from contrast-enhanced multidetector computed tomography (MDCT) images with bolus tracking and helical scanning. Nine canine models of left anterior descending artery (LAD) stenosis were prepared and underwent MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min) to study a wide range of flows. Neutron-activated microspheres were injected to document MBF during adenosine infusion. Six animals underwent dynamic MDCT perfusion imaging, and K1 and k2, which represent the first-order transfer constants from left ventricular blood to myocardium and from myocardium to the vascular system, respectively, were measured using a compartment model. The results were compared against microsphere MBF measurements, and the extraction fraction (E) of contrast agent and the mean value of K1/k2 were calculated. Six animals then underwent helical MDCT perfusion imaging during adenosine infusion. Prior to discontinuation of the

本文言語英語
ホスト出版物のタイトルIEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010
ページ2573-2577
ページ数5
DOI
出版ステータス出版済み - 2010
イベント2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 - Knoxville, TN, 米国
継続期間: 30-10-2010 → 06-11-2010

出版物シリーズ

名前IEEE Nuclear Science Symposium Conference Record
ISSN(印刷版)1095-7863

会議

会議2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
国/地域米国
CityKnoxville, TN
Period30-10-10 → 06-11-10

All Science Journal Classification (ASJC) codes

  • 放射線
  • 核物理学および高エネルギー物理学
  • 放射線学、核医学およびイメージング

フィンガープリント

「Quantification of myocardial blood flow using the combination of bolus tracking and time-registered helical multidetector CT angiography during adenosine stress」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル