Quantitative measurement of regional cerebral blood flow with I-123 IMP SPECT: A correction of the microsphere model by global extraction between artery and internal jugular vein

  • Gen Takeshita
  • , Hiroshi Toyama
  • , Kaori Nakane
  • , Hisato Maeda
  • , Kazuhiro Katada
  • , Akira Takeuchi
  • , Sukehiko Koga

研究成果: ジャーナルへの寄稿学術論文査読

2   !!Link opens in a new tab 被引用数 (Scopus)

抄録

Quantitative measurements of regional cerebral blood flow with N-isopropyl-(Iodine 123)p-iodoamphetamine (I-123 IMP) as a microsphere model were performed in forty cases. The regional cerebral blood flow values obtained with I-123 IMP were slightly underestimated compared with those of Xe-133 inhalation methods (y=0.90x-2.1, r=0.85, p< 0.01). After correction by global extraction (87 %) between the artery and internal jugular vein, which was measured in four patients by means of a catheter technique, the underestimation of the values obtained with I-123 IMP was improved (y=1.0x-2.4, r=0.85, p< 0.01). Several problems in the accurate quantitative measurement of regional cerebral blood flow with I-123 IMP are discussed.