メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT: Quantitative assessment of emphysematous changes in smokers' lung parenchyma

  • Hisanobu Koyama
  • , Yoshiharu Ohno
  • , Youichi Yamazaki
  • , Keiko Matsumoto
  • , Yumiko Onishi
  • , Daisuke Takenaka
  • , Takeshi Yoshikawa
  • , Mizuho Nishio
  • , Sumiaki Matsumoto
  • , Kenya Murase
  • , Yoshihiro Nishimura
  • , Kazuro Sugimura

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

抄録

Objectives: To determine the capability of reduced-dose chest CT with three-dimensional (3D) automatic exposure control (AEC) on quantitative assessment of emphysematous change in smoker' lung parenchyma, compared to standard chest CT. Methods: Twenty consecutive smoker patients (mean age 62.8 years) underwent CT examinations using a standard protocol (150 mAs) and a protocol with 3D-AEC. In this study, the targeted standard deviations number was set to 160. For quantitative assessment of emphysematous change in lung parenchyma in each subject using the standard protocol, a percentage of voxels less than -950 HU in the lung (%LAA -950) was calculated. The 3D-AEC protocol's %LAA was computed from of voxel percentages under selected threshold CT value. The differences of radiation doses between these two protocols were evaluated, and %LAAs -950 was compared with the 3D-AEC protocol %LAAs. Results: Mean dose length products were 780.2 ± 145.5 mGy cm (standard protocol), and 192.0 ± 95.9 (3D-AEC protocol). There was significant difference between them (paired Student's t test, p < 0.00001). Meanwhile, only setting -960 HU yielded no significant difference (paired Student's t test, p = 0.32) between %LAAs -950 and 3D-AEC protocol %LAAs. In adopting the feasible threshold CT values of the 3D-AEC protocol, the 3D-AEC protocol %LAAs were significantly correlated with %LAAs -950 (r = 0.98, p < 0.001) and limits of agreement from Bland-Altman analysis was 0.52 ± 4.3%. Conclusions: Changing threshold CT values demonstrated that reduced-dose chest CT with 3D-AEC can substitute for the standard protocol in assessments of emphysematous change in smoker' lung parenchyma.

本文言語英語
ページ(範囲)1330-1334
ページ数5
ジャーナルEuropean journal of radiology
巻81
号6
DOI
出版ステータス出版済み - 06-2012
外部発表はい

All Science Journal Classification (ASJC) codes

  • 放射線学、核医学およびイメージング

フィンガープリント

「Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT: Quantitative assessment of emphysematous changes in smokers' lung parenchyma」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル