TY - JOUR
T1 - Repetitive simulation training with novel 3D-printed sinus models for functional endoscopic sinus surgeries
AU - Suzuki, Masanobu
AU - Miyaji, Kou
AU - Watanabe, Ryosuke
AU - Suzuki, Takayoshi
AU - Matoba, Kotaro
AU - Nakazono, Akira
AU - Nakamaru, Yuji
AU - Konno, Atsushi
AU - Psaltis, Alkis James
AU - Abe, Takashige
AU - Homma, Akihiro
AU - Wormald, Peter John
N1 - Publisher Copyright:
© 2022 The Authors. Laryngoscope Investigative Otolaryngology published by Wiley Periodicals LLC on behalf of The Triological Society.
PY - 2022/8
Y1 - 2022/8
N2 - Background: The purpose of this study was to find a utility of a newly developed 3D-printed sinus model and to evaluate the educational benefit of simulation training with the models for functional endoscopic sinus surgery (FESS). Material and methods: Forty-seven otolaryngologists were categorized as experts (board-certified physicians with ≥200 experiences of FESS, n = 9), intermediates (board-certified physicians with <200 experiences of FESS, n = 19), and novices (registrars, n = 19). They performed FESS simulation training on 3D-printed models manufactured from DICOM images of computed tomography (CT) scan of real patients. Their surgical performance was assessed with the objective structured assessment of technical skills (OSATS) score and dissection quality evaluated radiologically with a postdissection CT scan. First we evaluated the face, content, and constructive values. Second we evaluated the educational benefit of the training. Ten novices underwent training (training group) and their outcomes were compared to the remaining novices without training (control group). The training group performed cadaveric FESS surgeries before and after the repetitive training. Results: The feedback from experts revealed high face and content value of the 3D-printed models. Experts, intermediates, and novices demonstrated statistical differences in their OSATS scores (74.7 ± 3.6, 58.3 ± 10.1, and 43.1 ± 11.1, respectively, p <.001), and dissection quality (81.1 ± 13.1, 93.7 ± 15.1, and 126.4 ± 25.2, respectively, p <.001). The training group improved their OSATS score (41.1 ± 8.0 to 61.1 ± 6.9, p <.001) and dissection quality (122.1 ± 22.2 to 90.9 ± 10.3, p =.013), while the control group not. After training, 80% of novices with no prior FESS experiences completed surgeries on cadaver sinuses. Conclusion: Repeated training using the models revealed an initial learning curve in novices, which was confirmed in cadaveric mock FESS surgeries. Level of evidence: N/A.
AB - Background: The purpose of this study was to find a utility of a newly developed 3D-printed sinus model and to evaluate the educational benefit of simulation training with the models for functional endoscopic sinus surgery (FESS). Material and methods: Forty-seven otolaryngologists were categorized as experts (board-certified physicians with ≥200 experiences of FESS, n = 9), intermediates (board-certified physicians with <200 experiences of FESS, n = 19), and novices (registrars, n = 19). They performed FESS simulation training on 3D-printed models manufactured from DICOM images of computed tomography (CT) scan of real patients. Their surgical performance was assessed with the objective structured assessment of technical skills (OSATS) score and dissection quality evaluated radiologically with a postdissection CT scan. First we evaluated the face, content, and constructive values. Second we evaluated the educational benefit of the training. Ten novices underwent training (training group) and their outcomes were compared to the remaining novices without training (control group). The training group performed cadaveric FESS surgeries before and after the repetitive training. Results: The feedback from experts revealed high face and content value of the 3D-printed models. Experts, intermediates, and novices demonstrated statistical differences in their OSATS scores (74.7 ± 3.6, 58.3 ± 10.1, and 43.1 ± 11.1, respectively, p <.001), and dissection quality (81.1 ± 13.1, 93.7 ± 15.1, and 126.4 ± 25.2, respectively, p <.001). The training group improved their OSATS score (41.1 ± 8.0 to 61.1 ± 6.9, p <.001) and dissection quality (122.1 ± 22.2 to 90.9 ± 10.3, p =.013), while the control group not. After training, 80% of novices with no prior FESS experiences completed surgeries on cadaver sinuses. Conclusion: Repeated training using the models revealed an initial learning curve in novices, which was confirmed in cadaveric mock FESS surgeries. Level of evidence: N/A.
KW - 3D printer
KW - cadaver surgery
KW - endoscopic surgery
KW - surgical education
KW - surgical training
UR - https://www.scopus.com/pages/publications/85134465401
UR - https://www.scopus.com/pages/publications/85134465401#tab=citedBy
U2 - 10.1002/lio2.873
DO - 10.1002/lio2.873
M3 - Article
AN - SCOPUS:85134465401
SN - 2378-8039
VL - 7
SP - 943
EP - 954
JO - Laryngoscope investigative otolaryngology
JF - Laryngoscope investigative otolaryngology
IS - 4
ER -