TY - JOUR
T1 - Results of isolated valve replacement in hemodialysis patients
AU - Kato, Wataru
AU - Tajima, Kazuyoshi
AU - Terasawa, Sachie
AU - Tanaka, Keisuke
AU - Usui, Akihiko
AU - Ueda, Yuichi
PY - 2007/10
Y1 - 2007/10
N2 - Frequent bleeding complications and poor long-term results have been reported after valve replacement in hemodialysis patients. We use mainly bileaflet mechanical valves with low-dose warfarin therapy (target international normalized ratio, 1.8-2.0) in such cases. Data of 27 hemodialysis patients undergoing isolated valve replacement from 1993 to 2002 were retrospectively analyzed. Bileaflet mechanical valves were selected in 23 patients and bioprostheses in 4. Those with mechanical valves were treated with mild anticoagulation therapy. There were 3 (11.1%) early deaths due to ischemic colitis, interstitial pneumonia, and ventricular arrhythmia. There were 3 late deaths and 5 bleeding complications during follow-up. The overall survival rate was 85.2% at 3 years and 72.9% at 5 years. The survival rate of patients with mechanical valves was 82.6% at 3 years and 76.7% at 5 years. One patient with a bioprosthesis experienced structural valvular deterioration after 3 years. The results demonstrate an acceptable long-term outcome. A bileaflet mechanical valve managed with mild anticoagulation therapy is a reasonable strategy for hemodialysis patients.
AB - Frequent bleeding complications and poor long-term results have been reported after valve replacement in hemodialysis patients. We use mainly bileaflet mechanical valves with low-dose warfarin therapy (target international normalized ratio, 1.8-2.0) in such cases. Data of 27 hemodialysis patients undergoing isolated valve replacement from 1993 to 2002 were retrospectively analyzed. Bileaflet mechanical valves were selected in 23 patients and bioprostheses in 4. Those with mechanical valves were treated with mild anticoagulation therapy. There were 3 (11.1%) early deaths due to ischemic colitis, interstitial pneumonia, and ventricular arrhythmia. There were 3 late deaths and 5 bleeding complications during follow-up. The overall survival rate was 85.2% at 3 years and 72.9% at 5 years. The survival rate of patients with mechanical valves was 82.6% at 3 years and 76.7% at 5 years. One patient with a bioprosthesis experienced structural valvular deterioration after 3 years. The results demonstrate an acceptable long-term outcome. A bileaflet mechanical valve managed with mild anticoagulation therapy is a reasonable strategy for hemodialysis patients.
UR - http://www.scopus.com/inward/record.url?scp=36348964848&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=36348964848&partnerID=8YFLogxK
U2 - 10.1177/021849230701500506
DO - 10.1177/021849230701500506
M3 - Article
C2 - 17911065
AN - SCOPUS:36348964848
VL - 15
SP - 386
EP - 391
JO - Asian Cardiovascular and Thoracic Annals
JF - Asian Cardiovascular and Thoracic Annals
SN - 0218-4923
IS - 5
ER -