TY - JOUR
T1 - Role of percutaneous veno-arterial extracorporeal membrane oxygenation as bridge to left ventricular assist device
AU - Toda, Koichi
AU - Fujita, Tomoyuki
AU - Seguchi, Osamu
AU - Yanase, Masanobu
AU - Nakatani, Takeshi
N1 - Publisher Copyright:
© The Japanese Society for Artificial Organs 2017.
PY - 2018/3
Y1 - 2018/3
N2 - Percutaneous veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides emergency circulatory support for cardiogenic shock patients and is used as a bridge to a left ventricular assist device (LVAD). The purpose of this study was to determine risk factors for LVAD implantation in patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. We retrospectively investigated 32 consecutive LVAD patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. Twenty-nine patients (91%) were intubated, and their serum creatinine and total bilirubin levels before LVAD implantation were 2.1 ± 2.0 and 3.7 ± 3.7 mg/dl, respectively. Patients were supported by LVAD for 495 ± 393 days, during which 15 died, 6 recovered native cardiac functions and LVAD was explanted, and 11 underwent heart transplantation. Multivariate logistic regression analysis revealed that a preoperative left ventricular end-diastolic diameter (LVDd) ≤54 mm was a significant predictor of 90-day mortality after LVAD implantation (OR 13.64; 95% CI 1.081–172.0; p = 0.0433) and freedom from death during LVAD support was significantly worse in patients with an LVDd ≤54 mm. Furthermore, preoperative LVDd was positively correlated with postoperative right ventricular stroke work index (r = 0.739, p < 0.0001) and patients with an LVDd ≤54 mm had significantly worse postoperative right ventricular, renal, and hepatic functions. We demonstrated that percutaneous VA-ECMO could be utilized as a bridge to long-term LVAD in selected patients. Our results suggest that preoperative LVDd is a useful predictor of mortality and right ventricular function after LVAD implantation in patients requiring VA-ECMO, in whom assessment of right ventricular function is challenging.
AB - Percutaneous veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides emergency circulatory support for cardiogenic shock patients and is used as a bridge to a left ventricular assist device (LVAD). The purpose of this study was to determine risk factors for LVAD implantation in patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. We retrospectively investigated 32 consecutive LVAD patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. Twenty-nine patients (91%) were intubated, and their serum creatinine and total bilirubin levels before LVAD implantation were 2.1 ± 2.0 and 3.7 ± 3.7 mg/dl, respectively. Patients were supported by LVAD for 495 ± 393 days, during which 15 died, 6 recovered native cardiac functions and LVAD was explanted, and 11 underwent heart transplantation. Multivariate logistic regression analysis revealed that a preoperative left ventricular end-diastolic diameter (LVDd) ≤54 mm was a significant predictor of 90-day mortality after LVAD implantation (OR 13.64; 95% CI 1.081–172.0; p = 0.0433) and freedom from death during LVAD support was significantly worse in patients with an LVDd ≤54 mm. Furthermore, preoperative LVDd was positively correlated with postoperative right ventricular stroke work index (r = 0.739, p < 0.0001) and patients with an LVDd ≤54 mm had significantly worse postoperative right ventricular, renal, and hepatic functions. We demonstrated that percutaneous VA-ECMO could be utilized as a bridge to long-term LVAD in selected patients. Our results suggest that preoperative LVDd is a useful predictor of mortality and right ventricular function after LVAD implantation in patients requiring VA-ECMO, in whom assessment of right ventricular function is challenging.
UR - http://www.scopus.com/inward/record.url?scp=85028801899&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85028801899&partnerID=8YFLogxK
U2 - 10.1007/s10047-017-0984-3
DO - 10.1007/s10047-017-0984-3
M3 - Article
C2 - 28871334
AN - SCOPUS:85028801899
SN - 1434-7229
VL - 21
SP - 39
EP - 45
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 1
ER -