メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Short- and long-term adverse events in patients on temporary circulatory support before durable ventricular assist device: An IMACS registry analysis

  • Van Khue Ton
  • , Rongbing Xie
  • , Jaime A. Hernandez-Montfort
  • , Bart Meyns
  • , Takeshi Nakatani
  • , Masanobu Yanase
  • , Steve Shaw
  • , Stephen Pettit
  • , Ivan Netuka
  • , James Kirklin
  • , Daniel J. Goldstein
  • , Jennifer Cowger

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

抄録

BACKGROUND: Patients with cardiogenic shock (CS) needing temporary circulatory support (TCS) have poor survival rates after implantation of durable ventricular assist device (dVAD). We aimed to characterize post-dVAD adverse event burden and survival rates in patients requiring pre-operative TCS. METHOD: We analyzed 13,511 adults (Interagency Registry for Mechanically Assisted Circulatory Support [INTERMACS] Profiles 1–3) with continuous-flow dVADs in International Society for Heart and Lung Transplantation Registry for Mechanically Assisted Circulatory Support (2013–2017) according to the need for pre-operative TCS (n = 5,632) vs no TCS (n = 7,879). Of these, 726 (5.4%) had biventricular assist devices (BiVAD). Furthermore, we compared prevalent rates (events/100 patient-months) of bleeding, device-related infection, hemorrhagic and ischemic cerebrovascular accidents (hemorrhagic cerebral vascular accident [hCVA], and ischemic cerebral vascular accident [iCVA]) in early (<3 months) and late (≥3 months) post-operative periods. RESULTS: TCS included extracorporeal membrane oxygenation (ECMO) (n = 1,138), intra-aortic balloon pump (IABP) (n = 3,901), and other TCS (n = 593). Within 3 post-operative months, there were more major bleeding and cerebrovascular accidents (CVAs) in patients with pre-operative ECMO (events/100 patient-months rates: bleeding = 19, hCVA = 1.6, iCVA = 2.8) or IABP (bleeding = 17.3, hCVA = 1.5, iCVA = 1.5) vs no TCS (bleeding = 13.2, hCVA = 1.1, iCVA = 1.2, all p < 0.05). After 3 months, adverse events were lower and similar in all groups. Patients with ECMO had the worst short- and long-term survival rates. Patients with BiVAD had the worst survival rate regardless of need for pre-operative TCS. CVA and multiorgan failures were the common causes of death for patients with TCS and patients without TCS. CONCLUSIONS: Patients requiring TCS before dVAD had a sicker phenotype and higher rates of early post-operative adverse events than patients without TCS. ECMO was associated with very high early ischemic stroke, bleeding, and mortality. The extreme CS phenotype needing ECMO warrants a higher-level profile status, such as INTERMACS “0.”

本文言語英語
ページ(範囲)342-352
ページ数11
ジャーナルJournal of Heart and Lung Transplantation
巻39
号4
DOI
出版ステータス出版済み - 04-2020
外部発表はい

All Science Journal Classification (ASJC) codes

  • 外科
  • 呼吸器内科
  • 循環器および心血管医学
  • 移植

フィンガープリント

「Short- and long-term adverse events in patients on temporary circulatory support before durable ventricular assist device: An IMACS registry analysis」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル