抄録

Objectives: The objective was to evaluate the significance of a portable sleep-monitoring device (Apnomonitor 5®, Chest Co., Tokyo, Japan) to diagnose sleep apnea syndrome (SAS). Methods: The Apnomonitor 5® comprised an oronasal thermistor, a pulse oximeter, chest and abdominal belts to monitor the circumferences of the chest and abdomen, a microphone to monitor tracheal sound, a position detector, and an integrative unit. This screening device was commercially available and it had been used to diagnose SAS in our country. Twenty-two consecutive adults who attended Inazawa City Hospital who were suspected for SAS were prospectively enrolled and they undertook the standard polysomnography (PSG) and Apnomonitor 5® simultaneously. The designated polysomnographers analyzed the records of the PSG and Apnomonitor 5®. These sleep and respiratory parameters of the devices were compared, the results of which were double-checked by the designated sleep specialist. Results: The apnea-hypopnea index (AHI), apnea index, total number of apnea, and oxygen desaturation index obtained by the PSG and Apnomonitor 5® correlated significantly, whereas the averaged sleep time, total number of hypopnea, hypopnea index, and nadir oxygen saturation differed between the devices. The sensitivity of the Apnomonitor 5® versus PSG was 95% in the SAS patients with the AHI ≥ 15. Conclusions: The Apnomonitor 5® can be a sensitive and useful screening device for SAS especially in patients with the AHI ≥ 15.

本文言語英語
ページ(範囲)176-180
ページ数5
ジャーナルAuris Nasus Larynx
36
2
DOI
出版ステータス出版済み - 04-2009
外部発表はい

All Science Journal Classification (ASJC) codes

  • 外科
  • 耳鼻咽喉科学

フィンガープリント

「Significance of a screening device (Apnomonitor 5®) for sleep apnea syndrome」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル