Six-month clinical and angiographic outcome of the new, less shortening Wallstent in native coronary arteries

Yukio Ozaki, David Keane, Peter Ruygrok, Willem J. Van Der Giessen, Pim De Feyter, Patrick W. Serruys

研究成果: Article査読

38 被引用数 (Scopus)

抄録

Background: The new, less shortening, self-expanding Wallstent is characterized by longitudinal flexibility, a protective membrane, a low profile, and a customized range of diameters (3.5 to 6.0 mm). The recent modification of the braiding angle of the Wallstent has resulted in anew device with less shortening on expansion and a concomitant reduction in radial force. We hypothesized that the enforced mechanical remodeling produced by the selection of an oversized Wallstent might result in improved accommodation of subsequent reactive intimal hyperplasia and prevention of chronic recoil of the vessel. Methods and Results: To prove this hypothesis, we recently implanted 44 new, less shortening Wallstents in 35 native coronary arteries in 35 patients with acute or threatened closure after balloon angioplasty, according to a strategy of oversizing of Wallstent diameter and complete coverage of the lesion length. The initial and 6-month follow-up angiogram were analyzed with a computer-based quantitative coronary angiography (QCA) system. Acute gain (minimal luminal diameter [MLD] post minus MLD pre) and late loss (MLD post minus MLD at follow-up) were examined. Stent deployment was successful in 44 of 44 attempts (100%). Nominant stent diameter used was 1,40 mm larger than the maximal vessel diameter. One patient (3%) with a dilated but unstended lesion proximal to the stended segment sustained a subacute occlusion on day 1 associated with myocardial infarction. Event-free survival at 30 days after stent implantation was 97% (34 of 35 patients). Of the 34 patients eligible for 6-month angiographic follow-up 3 who were asymptomatic declined repeat angiography. MLD (and percent diameter stenosis [% DS]) changed from 0.83 ± 0.50 mm (72%) pre through 3.06 ± 0.48 mm (15%) post to 2.27% ± 0.74 mm (28%) at follow-up. Acute gain was 2.23 ± 0.63 mm, and late loss was 0.78 ± 0.61 mm. Angiographic restenosis (>50% DS) was observed in 5 of 31 patients (16%) at 6 months, all of whom underwent repeat angioplasty. Thus, the overall event- free survival at 6-months follow-up was 83% (29 of 35 patients). Conclusions: The oversized Wallstent implantation with complete coverage of lesion length conveyed a favorable 6-month clinical and angiographic outcome. The large acute gain obtained by the Wallstent afforded greater accommodation of the subsequent late loss. The enforced mechanical remodeling by oversized new Wallstents may result in prevention of acute and chronic recoil of the vessel wall and subsequently a lower restenosis rate at follow-up.

本文言語English
ページ(範囲)2114-2120
ページ数7
ジャーナルCirculation
93
12
DOI
出版ステータスPublished - 15-06-1996
外部発表はい

All Science Journal Classification (ASJC) codes

  • 循環器および心血管医学
  • 生理学(医学)

フィンガープリント

「Six-month clinical and angiographic outcome of the new, less shortening Wallstent in native coronary arteries」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル