SU‐E‐T‐767: Improvement of Dose Conformity and Homogeneity of the Dose Distribution on Irregular‐Surface‐Compensator Based Breast Irradiation

  • R. Yada
  • , N. Hayashi
  • , M. Nozue
  • , H. Sai
  • , K. Yamada
  • , Y. Kato
  • , R. Yamanaka

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Purpose: For irregular‐surface‐compensator based breast irradiation (ISCBBI), the skin flash tool application (SFTA) is useful to expand the intensity map with considering the respiratory motion. However, the default recommended setting of SFTA is assumed for large breast case. The purpose of this study is to verify the influence of SFTA and to establish the suitable setting on the treatment planning for ISCBBI in our hospital. Methods and Materials: Twenty patients with breast cancer were selected for this study. All patients were fixed by an arm support with a combination of Vaclok vacuum cushion. A 6 MV photon beam from Varian 21EX linear accelerator that equipped with 5 mm width multi‐leaf collimator was used. The plans were created by Eclipse treatment planning system. The spatial resolution of SFTA was 2.5 mm. The intensity maps of ISCBBI were compared. These intensity maps and the transmission factors on some region‐of‐interest (ROI) area were evaluated. ROIs were defined at superior side, center area and inferior side. After the planning, the rehearsals of leaf motion were performed. Results: The image‐guided setup error with considering respiratory motion was within 3 mm. The satisfactory intensity map was created for ISCBBI when the suitable setting was defined at ROIs. The conformable intensity maps on ISCBBI were obtained when the transmission factors with ranging from 0.45 to 0.60 and the penetration depths of 45% were selected for ISCBBI planning, respectively. The suitable setting reduced the dynamic leaf motion error during delivery of ISCBBI. Conclusion: The unsuitable setting of ISCBBI planning leads to make inconformity of intensity map. The optimal number of transmission factor to obtain the satisfactory intensity map for ISCBBI in our hospital are approximately 0.5. To classify the setting for ISCBBI planning in patient's condition, the further evaluations and measurements are required.

本文言語英語
ページ(範囲)3667
ページ数1
ジャーナルMedical Physics
38
6
DOI
出版ステータス出版済み - 06-2011
外部発表はい

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を

All Science Journal Classification (ASJC) codes

  • 生物理学
  • 放射線学、核医学およびイメージング

フィンガープリント

「SU‐E‐T‐767: Improvement of Dose Conformity and Homogeneity of the Dose Distribution on Irregular‐Surface‐Compensator Based Breast Irradiation」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル