メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Surgical intervention for instability of the craniovertebral junction

  • Masakazu Takayasu
  • , Masahiro Aoyama
  • , Masahiro Joko
  • , Mikinobu Takeuchi

研究成果: ジャーナルへの寄稿総説査読

15   !!Link opens in a new tab 被引用数 (Scopus)

抄録

Surgical approaches for stabilizing the craniovertebral junction (CVJ) are classified as either anterior or posterior approaches. Among the anterior approaches, the established method is anterior odontoid screw fixation. Posterior approaches are classified as either atlanto-axial fixation or occipito-cervical (O-C) fixation. Spinal instrumentation using anchor screws and rods has become a popular method for posterior cervical fixation. Because this method achieves greater stability and higher success rates for fusion without the risk of sublaminar wiring, it has become a substitute for previous methods that used bone grafting and wiring. Several types of anchor screws are available, including C1/2 transarticular, C1 lateral mass, C2 pedicle, and translaminar screws. Appropriate anchor screws should be selected according to characteristics such as technical feasibility, safety, and strength. With these stronger anchor screws, shorter fixation has become possible. The present review discusses the current status of surgical interventions for stabilizing the CVJ.

本文言語英語
ページ(範囲)465-475
ページ数11
ジャーナルneurologia medico-chirurgica
56
8
DOI
出版ステータス出版済み - 2016
外部発表はい

All Science Journal Classification (ASJC) codes

  • 外科
  • 臨床神経学

フィンガープリント

「Surgical intervention for instability of the craniovertebral junction」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル